GE ZET958, ZET938 manual Threnheit or Celsius Temperature selection, Conversion, Llt o, Wall Oven

Page 12

t' threnheit or Celsius

temperature selection

A"llt o

conversion

_bur oven conlrol i,s sel lo use lhe Fakre_keil

lemperalure seleclions, bul you may eha_ge lkis to use the Cel,siu,s ,se#clio_,s.

1 Press the BAKE and BROIL HIGH/LOW

pads (on double oven models, use the upper

oven controls) at the same time ti)r 3 seconds until the display shows "SK"

2 Press the BROIL HIGH/LOW and COOK TIME pads at the same time. The display will show "F" ([_ahrenheit).

Press the BROIL HIGH/LOW and COOK TIME pads again at the same time. This will show "(7' (Celsius).

3 Press the START pad. The new setting will be

displayed tot both ovens.

NOTF: On double over_ mode& the uew setti*_e,"will be disJdayed Jbr both ove_,s.

1,17zenusir_g"eonve( tion bake, the Auto I_ecipe'"

Couver, siou /kature will automatically _onvert entered r_q'ular bakir_g"lempe*r_tu*_¢,to _onvection baki_g" tem/:e*rcture,_.

Once lhe fi_alu_, is activaled, the displa)' will show lhe actual couve*'ted (*_,duced) tempe*vltu*_. For example, !Jyou er_te*"a _z'g'ular rec@e tempe*rltare (_/ 350°F and pre,_s the START pad, the display will show "CON" and the converted tempe*rlture ({/"325°t{"

NO_I_2: This J;¢alure doe,s not co*n_erlconveclio*_bake eooki_g"lime,s, o_dy r(_q'ularbaki_g lem/)eralures.

To Activate the Feature:

1 Press the BAKE and BROIL HIGH/LOW

pads (on double oven Inodels, use the upper

oven controls) at the same time fl)r 3

seconds, until the display shows "SE"

2 Press the CONV BAKE/1 RACK pad. The display will show "CON OFE" Press the CONV BAKE/1 RACK pad again. The display will show "CON ON."

3 Press the START pad.

To deactivate the feature, repeat steps 1-3 abme but press the START pad when "CON OFF" is in the display.

Special Features

Wall Oven

@.@

@

@+@

@

12

Image 12
Contents Manual Protective shitsOing f!lm IntroductionBebre using your wall oven ServiceSave time Money Louisville,/.YKeep the oven free from grease buildup Do not store flammable materials in the ovenSAP 2 TY PRE CA U7 70NS Features of Your Wall Oven Design inJbrmationLlll Ove 41peamceay vaUTim 7bnesAtures ClockOven Control, Clock & Timer MerCLEAR/OFF pad doe, not qf, ct the time Using the timer Control lockout Press tile Timer ON/OFF pad77,¢acu,slme¢lrvifi be rdabwd it memor after a power fifihm CLEAR/OFF pad does tol qff¢cl ttte timeSpecial Features EcialEatures q 7bnes atHour Or clockBlackout Threnheit or Celsius Temperature selection ConversionLlt o Wall OvenUsing the Sabbath Feature How to set@@@9@@@@@@ Sabbath Iature@@@ AutomaticStop +63 How to set Oven jbr baking or roasting When cooking Is completeBaking or Roasting CheckHeating and pan placement AluminumHow to set Oven jbr broiling Follow suggested rack positions Broiling GuideN07 Broil will not work !/the lemperatu probe is phlgq,din Modds Broiling guideRack RainBroiling ModelsPoAmzitgoWnzi,msm Using the timed baking and roasting EaturesStop Timed BakingHow to set Delayed start Automatic Stop Using tile number pads, enter tile desired bakino timeUsing tile number pads, enter tile time Reed to add addiliotal lime lo the lerglh t lhe Cookbg limeUsing the Probe 7Emperature probe?dl Oven Placement For Proper Probe PlacementProbe How to set Oven Jot roasting when using the probe @@@ @@@@@9@@@@100K Convection FitnRach convection bahing Multi-rack convection bahingCooking Convection Roasting Q/liil/i 1 li/it\l\X\\ BroilerpanHow to set Oven./br convection Baking or roasting Using the Convection Oven@@@@@@@@@ Convection RoastingHow to set Oven jor Convection Roasting when using the probe@@@@@@@@@@ Lh,p,.ol,i.s,,,,,,o,,,4/o,,,lh,,Ji,o&/i,r,,#Z,Ji,,,,l@@9@@@@@@ @@@@@@@@@ An immediateTimed onvection Baking Automatic Utomatidl3Convection bahbg section fir more information Nolo m wig hara /an whib ooliKwith thisHow to set the oven Jbr warming WarmingHow to set the oven Jot proofing ProofingAdjust the Oven Thermostat MargarineThermostat Will /bctUsing the Self Cleaning Oven How to set Oven jot cleaningDean cycle ?/// OvenHow to Delay the start of c#aning Lean ycleAble Re and leaning Pack tging tapeMetal parts Broiler pan GridLoi-o ff 07e7l OOYDo not l!fi th door by th handh 1471ll OvenPu?movable Oven heating elementsOven .flOOr Press down and pull out the removableReconnect electrical power to the oven Light bulbs PTvbe07 gvZ N07 The glass eover sholdd be removed mdy whenSave time Money Ajust the Oven TlwrmostatDo it you*se/! section Trouble Shooting tips Before You Call For ServicePage Page Warranty Registration Department Box Eo.r ron*idenrein GEa.d r,n. i. the t!.S.t,,H-*reeatBenefits Include Backed by GE No out-of-pocket expensesFirst Nam I I I I I AddressSt l-CtI I I I I INLstlml ZipService Contracts Accessories800.626 In-Home RepairWarranty Pvm the Date Oginal PuwhaseOnveclion I,lall Oven

ZET938, ZET958 specifications

The GE ZET958 and ZET938 are advanced digital electrical measuring devices designed for a wide range of applications in the power sector. These devices offer a multitude of features that enhance efficiency, reliability, and performance in electrical monitoring and protection systems.

One of the main features of the GE ZET958 and ZET938 is their ability to provide precise and real-time measurement of electrical parameters such as voltage, current, frequency, and power factor. This capability allows engineers and technicians to monitor the health of electrical systems and make informed decisions to optimize performance and prevent potential failures.

Both models are equipped with state-of-the-art digital signal processing technology, which ensures accurate data acquisition and processing. This technology minimizes errors and enhances the precision of measurements, making these devices particularly suitable for critical applications where reliability is paramount.

The ZET958 model is designed for high-end applications and supports up to 12 measurement inputs, allowing it to monitor multiple circuits simultaneously. It features a large, intuitive display that provides easy access to live data and historical trends, helping operators quickly identify issues and trends over time. Additionally, the ZET958 possesses advanced communication protocols, including Modbus and DNP3, enabling seamless integration into existing monitoring systems and facilitating remote access and control.

On the other hand, the ZET938 model is tailored for general-purpose applications, offering a more compact design without compromising on essential features. While it supports fewer measurement inputs compared to the ZET958, it still provides comprehensive monitoring capabilities, making it ideal for smaller installations or as a supplementary device in larger systems.

Both the ZET958 and ZET938 incorporate robust security features that help protect sensitive data from unauthorized access. This is crucial in today’s rapidly evolving digital landscape, where cybersecurity threats are increasingly prevalent.

Furthermore, the user-friendly interface of both models simplifies configuration and setup, allowing for quicker deployments. Advanced data logging capabilities ensure that users can review historical data efficiently, which is valuable for analysis and compliance purposes.

In summary, the GE ZET958 and ZET938 are powerful digital measuring devices that cater to a wide range of electrical monitoring needs. Their combination of precision, advanced technology, and user-friendly features make them reliable solutions for enhancing the efficiency and safety of electrical systems. With these devices, industries can streamline operations while ensuring optimal performance and reliability.