Maytag MFI2568AEW manual Re-install the PCB

Page 15

Re-install the PCB:

1.Installation is the reverse order of removal

2.Tuck the right hand side of the PCB (the one you marked, right ?) into the slot on the right hand side of the white plastic tub. (Fig 20)

© 2007 Stephen Beck

Fig. 20

3.GENTLY press the left side of the PCB into the top and bottom clips till they snap closed, securing the PCB in place. (Figs. 21 & 22)

© 2007 Stephen Beck

Fig. 21

© 2007 Stephen Beck

Fig. 22

4.Re-attach the wire connectors to the PCB – they should naturally fall back into the proper place to connect back, and match your markings drawings you made when you took them off. Push the wires back into the chases alongside the PCB. (Fig 23)

© 2007 Stephen Beck

Fig. 23

© 2007 by Stephen Beck V1.0

Page 15 of 19

Use at your Own Risk

Image 15
Contents MFI2568AEW Important Safety Reminders and Legal Stuff Don’t Skip Technical stuff OverviewParts and Supplies List Unplug the fridge Step-By-Step proceduresView looking down from the top Ice/water dispenser Power to flapper door and water dispenserRemove the PCB from the fridge Fixing the HV Control BoardOne good cap Release Clip. All 4 connectors similar By Stephen Beck Use at your Own Risk Replace the Caps Positive Terminal NegativeMinus signs Negative Terminals Minus Signs Negative TerminalMinus Sign Minus Signs Caps Plus signs on PCB By Stephen Beck Use at your Own Risk Re-install the PCB By Stephen Beck Use at your Own Risk Testing the Fridge Caution Required Optional Plug the flapper door back View looking down from the top Ice/water dispenser