High Velocity Cartridge Filters

A. Exhaust

With all the filters in place, determine the total hood exhaust volume with a shortridge meter as follows:

1.All cooking equipment should be on. If the hood has internal short circuit make-up air, it should be turned off.

2.Measuring Velocities

Set up the shortridge meter. Leave all holes of Velgrid open. Do NOT tape over holes that are not over openings. The conversion factor takes this into account.

Position the grid over each filter as shown.

Take velocity readings for each filter.

3.*Calculate each filter’s volumetric flow rate by summing the flow rate of each individual filter in the hood.

4.*Calculate the total hood’s volumetric flow rate by summing the flow rate of each individual filter in the hood.

*Note: For best accuracy multiply the velocity of each filter by

its conversion factor and sum the flow rates. Averaging the velocity measured for all filters may cause error.

Nominal Filter Size (H x L)

Imperial

Metric

Inches

Millimeters

Conversion Factor

Conversion Factor

 

 

 

 

16 x 16

400 x 400

1.22 ft2

.113 m2

16 x 20

400 x 500

1.67 ft2

.155 m2

20 x 16

500 x 400

1.21 ft2

.112 m2

20 x 20

500 x 500

1.50 ft2

.139 m2

Example: Measured velocities for 20 x 20 filter = 282 fpm (5157 m/hr)

Flow rate for one filter

=

Conversion

x

Average

 

 

 

 

Factor

 

Velocity

 

 

(Imperial)

=

1.50

x

282 fpm

=

423.0 cfm

(Metric)

=

.139

x

5157 m/hr

=

717 m3/hr

Total hood flow rate =

(Filter 1 Flow Rate) +

… + (Filter X Flow Rate)

=

423.0 + 421.8 + 420.7 + 418.2 = 1683.7 cfm

=

717 + 717 + 715 + 711

= 2860 m3/hr

Fig. 29

1/2 width

1/2 height

Fig. 30

21 Proximity Hood

®

Image 21
Contents Installation, Operation and Maintenance Manual Table of Contents Receiving and Handling Hood WeightsInstallation Hood Installation OverviewRear Filler Panel Installation Instructions End Filler Panel Installation Instructions Hood Hanging HeightContinuous Capture Plenum Hoods Ductwork Exhaust SupplyElectrical Connections Installation Instructions External Supply Plenum InstallationHanging the Back Supply Plenum Installing the Back Supply PlenumHood Mounting Instructions Hanging the Hood with Back Supply PlenumFull Enclosure Panels Plate Shelf with Duct Enclosure Panels Passover Shelf with Duct Enclosure Panels Flat Backsplash Panel Backsplash Panel Installation InstructionsFire System Installation Duct Collar InstallationChecking for Balance Exhaust Air Balancing Baffles EabbBalancing the Kitchen Exhaust System Testing Hood Air Volume Baffle Filter Style Hoods ExhaustRotating Vane Anemometer Example for Perforated Face Supply Supply If Applicable185 + 187.0 fpm Example High Velocity Cartridge Filters Exhaust282 fpm 423.0 cfm Volume with a rotating vane anemometer as follows 1042 4012 m3/hr PRM Amerex Wiring Plan ViewEquipment Ansul Wiring Plan ViewHood Overall Wiring Plan ViewWiring for Switch Panels Maintenance Daily Maintenance Weekly MaintenancePeriodic Maintenance Proximity Hood Frequent Maintenance Grease Grabber Filter CleaningEquipment Required Cycles Filter Washing Frequency GuideTroubleshooting Problem Cold air can be felt by the cook at the hood Replacement Parts Maintenance Log Warranty

PN 458294 specifications

Greenheck Fan PN 458294 is a prominent product in the HVAC industry, designed to deliver high performance, efficiency, and reliability in various applications. This unit is widely recognized for its ability to optimize airflow while minimizing energy consumption, a feature that is becoming increasingly vital in current energy-conscious markets.

One of the key features of the Greenheck Fan PN 458294 is its robust construction. Built with durable materials, this fan is engineered to withstand harsh environmental conditions, making it suitable for both indoor and outdoor installations. The corrosion-resistant finish further enhances its resilience, ensuring a longer lifespan and reduced maintenance costs.

The fan is equipped with advanced aerodynamic designs that improve its airflow performance. This design focus not only maximizes the fan's efficiency but also provides quieter operation, which is a crucial factor in sensitive environments such as offices, schools, and hospitals. The noise reduction technology integrated into the unit helps maintain a comfortable atmosphere while keeping operational disturbances to a minimum.

In terms of technology, the Greenheck Fan PN 458294 features state-of-the-art motor technology that offers variable speed control. This capability allows users to adjust the fan's operation according to specific needs, enhancing energy efficiency while ensuring optimal airflow. The internally mounted motor and belt drive system contribute to reduced vibration and increased stability, further lowering wear and tear over time.

This fan also incorporates innovative control options, allowing for easy integration into existing building management systems. This smart technology enables users to monitor and adjust performance remotely, ensuring maximum efficiency and adaptability to changing operational demands.

Another noteworthy characteristic of the Greenheck Fan PN 458294 is its versatility. It can be utilized in a variety of applications, including industrial ventilation, commercial exhaust, and air supply systems. The wide range of available configurations and accessory options makes it an ideal choice for meeting diverse project requirements.

In conclusion, the Greenheck Fan PN 458294 stands out in the HVAC market due to its combination of robust construction, advanced aerodynamic design, innovative motor technology, and versatile application capabilities. As energy efficiency continues to be a priority in building design, this fan offers a reliable solution for maintaining optimal airflow while minimizing environmental impact.