Greenheck Fan PN 458294 manual Proximity Hood

Page 29

Grease Grabber™ Multi-Stage Filtration System

For use in Model GG__ Canopy Hoods Only

Installation

Note: Never install the Second Stage filter in the front filter channel. The Second Stage filter must be installed behind a UL Classified Grease-X-Tractor™ primary filter Model HE or GX.

1.Slide the top edge of the Second Stage filter into the top rear filter channel; Fig. 41.

2.Lifting the lower edge of the filter past the grease trough, continue to push the top of the filter into the channel.

3.When the filter is even with the bottom rear filter channel, set the filter into the channel; Fig. 42.

4.Slide the filter to one end of the hood and repeat until all the filters are installed. Make sure the filters are placed tightly together with no visible gaps.

5.Latch filters together by connecting hooks to handle on next filte; Fig. 43.

6.Install the Grease-X-Tractor™ primary filters in the same manner using the front filter channel.

 

 

 

Fig. 41

Fig. 42

 

 

 

Fig. 43

29 Proximity Hood

®

Image 29
Contents Installation, Operation and Maintenance Manual Table of Contents Receiving and Handling Hood WeightsRear Filler Panel Installation Instructions InstallationHood Installation Overview Continuous Capture Plenum Hoods End Filler Panel Installation InstructionsHood Hanging Height Electrical Connections Ductwork ExhaustSupply Installation Instructions External Supply Plenum InstallationHanging the Back Supply Plenum Installing the Back Supply PlenumHood Mounting Instructions Hanging the Hood with Back Supply PlenumFull Enclosure Panels Plate Shelf with Duct Enclosure Panels Passover Shelf with Duct Enclosure Panels Flat Backsplash Panel Backsplash Panel Installation InstructionsFire System Installation Duct Collar InstallationChecking for Balance Exhaust Air Balancing Baffles EabbBalancing the Kitchen Exhaust System Testing Hood Air Volume Baffle Filter Style Hoods ExhaustRotating Vane Anemometer Example for Perforated Face Supply Supply If Applicable185 + 187.0 fpm Example High Velocity Cartridge Filters Exhaust282 fpm 423.0 cfm Volume with a rotating vane anemometer as follows 1042 4012 m3/hr PRM Amerex Wiring Plan ViewEquipment Ansul Wiring Plan View Hood Overall Wiring Plan ViewWiring for Switch Panels Periodic Maintenance Maintenance Daily MaintenanceWeekly Maintenance Proximity Hood Frequent Maintenance Grease Grabber Filter CleaningEquipment Required Cycles Filter Washing Frequency GuideTroubleshooting Problem Cold air can be felt by the cook at the hood Replacement Parts Maintenance Log Warranty