Greenheck Fan PN 458294 manual End Filler Panel Installation Instructions, Hood Hanging Height

Page 5

End Filler Panel Installation Instructions

End filler panels may be shipped loose for field installaton or are facory mounted to the hood. If fillers are factory mounted to hood, skip this section.

1.Uncrate the hood and lay it on the floor with protective material between the hood and the floor.

2.Bolt the filler panels together with 5/16 in. bolts from the hardware package.

3.Position the filler panels on the hood and tack-weld them to the appropriate side of the hood.

4.To allow for ease of cleaning, caulk the external seams with

NSF Approved silicone caulk (GE SCS1009, or its equivalent). The caulk is not provided.

Note: Hood may be furnished with

 

 

finished end fillers when mounting

 

 

against a partial wall.

End Filler Panels

Fig. 3

Hood Hanging Height

The hood hanging height is critical, hanging the hood at the incorrect height may significantly reduce the ability for the hood to function properly and may be in violation of codes. The hood hanging height is given on the UL label located on the inside of the hood on the end panel. The distance given is from the front lip of the hood (shown in Fig. 4) to the surface of the cooking equipment.

Continuous Capture Plenum Hoods

Use the installation procedure described on page 4 for single island hoods; install and level both hoods. After leveling, secure the hoods together. Fasten the hoods together using u-clips and bolts. (Fig. 6) Caulk this joint with NSF Approved silicone caulk (GE SCS1009 or its equivalent). The caulk is not provided.

UL Vertical Distance

Above Cooking Surface

Fig. 4

Fig. 5

 

 

HOOD

CAULK

 

 

BOLT

 

ACORN NUT

 

Fig. 6 U-CLIP

Proximity Hood

®

Image 5
Contents Installation, Operation and Maintenance Manual Table of Contents Receiving and Handling Hood WeightsRear Filler Panel Installation Instructions InstallationHood Installation Overview Continuous Capture Plenum Hoods End Filler Panel Installation InstructionsHood Hanging Height Electrical Connections Ductwork ExhaustSupply Installation Instructions External Supply Plenum InstallationHanging the Back Supply Plenum Installing the Back Supply PlenumHood Mounting Instructions Hanging the Hood with Back Supply PlenumFull Enclosure Panels Plate Shelf with Duct Enclosure Panels Passover Shelf with Duct Enclosure Panels Flat Backsplash Panel Backsplash Panel Installation InstructionsFire System Installation Duct Collar InstallationChecking for Balance Exhaust Air Balancing Baffles EabbBalancing the Kitchen Exhaust System Testing Hood Air Volume Baffle Filter Style Hoods ExhaustRotating Vane Anemometer Example for Perforated Face Supply Supply If Applicable185 + 187.0 fpm Example High Velocity Cartridge Filters Exhaust282 fpm 423.0 cfm Volume with a rotating vane anemometer as follows 1042 4012 m3/hr PRM Amerex Wiring Plan ViewEquipment Ansul Wiring Plan ViewHood Overall Wiring Plan ViewWiring for Switch Panels Periodic Maintenance Maintenance Daily MaintenanceWeekly Maintenance Proximity Hood Frequent Maintenance Grease Grabber Filter CleaningEquipment Required Cycles Filter Washing Frequency GuideTroubleshooting Problem Cold air can be felt by the cook at the hood Replacement Parts Maintenance Log Warranty

PN 458294 specifications

Greenheck Fan PN 458294 is a prominent product in the HVAC industry, designed to deliver high performance, efficiency, and reliability in various applications. This unit is widely recognized for its ability to optimize airflow while minimizing energy consumption, a feature that is becoming increasingly vital in current energy-conscious markets.

One of the key features of the Greenheck Fan PN 458294 is its robust construction. Built with durable materials, this fan is engineered to withstand harsh environmental conditions, making it suitable for both indoor and outdoor installations. The corrosion-resistant finish further enhances its resilience, ensuring a longer lifespan and reduced maintenance costs.

The fan is equipped with advanced aerodynamic designs that improve its airflow performance. This design focus not only maximizes the fan's efficiency but also provides quieter operation, which is a crucial factor in sensitive environments such as offices, schools, and hospitals. The noise reduction technology integrated into the unit helps maintain a comfortable atmosphere while keeping operational disturbances to a minimum.

In terms of technology, the Greenheck Fan PN 458294 features state-of-the-art motor technology that offers variable speed control. This capability allows users to adjust the fan's operation according to specific needs, enhancing energy efficiency while ensuring optimal airflow. The internally mounted motor and belt drive system contribute to reduced vibration and increased stability, further lowering wear and tear over time.

This fan also incorporates innovative control options, allowing for easy integration into existing building management systems. This smart technology enables users to monitor and adjust performance remotely, ensuring maximum efficiency and adaptability to changing operational demands.

Another noteworthy characteristic of the Greenheck Fan PN 458294 is its versatility. It can be utilized in a variety of applications, including industrial ventilation, commercial exhaust, and air supply systems. The wide range of available configurations and accessory options makes it an ideal choice for meeting diverse project requirements.

In conclusion, the Greenheck Fan PN 458294 stands out in the HVAC market due to its combination of robust construction, advanced aerodynamic design, innovative motor technology, and versatile application capabilities. As energy efficiency continues to be a priority in building design, this fan offers a reliable solution for maintaining optimal airflow while minimizing environmental impact.