Greenheck Fan 452413 manual Installing Enclosure Panels

Page 12

Installing Enclosure Panels

Before installing the enclosure panels, make sure the hood is hung in position with all the ductwork attached and electrical connections completed.

Fig. 19

1.Position the end enclosure panels on the hood, and clamp into place with clamps provided or tack- weld the panels into place (Fig 19).

2.Fasten the end enclosure panels to the wall, method depends on wall construction. (fasteners are not provided)

If the hood is a double island, bolt the end enclosure panels together. (fasteners are not provided)

3.Position the front enclosure panel(s) on the hood, and bolt to the end enclosure panels with the 5/16 in. bolts provided in the hardware package.

4.Tack-weld or clamp the front enclosure panel(s) to the hood. If clamps are used, they must be positioned 4 in. (100 mm) from the ends, and in the center of the front enclosure panel.

5.To allow for ease of cleaning, caulk the external seams with NSF Approved silicone caulk (GE SCS1009, or its equivalent). The caulk is not provided.

6.Installation instructions may not be applicable for concrete ceilings.

12 Canopy Hood

®

Image 12
Contents Installation, Operation and Maintenance Manual Table of Contents Table of Contents Receiving and Handling StorageInstallation Hood Installation OverviewFiller Panel Installation Instructions Installing U-Channel Strip Hood Hanging HeightDouble Island Style Hoods Continuous Capture Plenum HoodsElectrical Connections Ductwork ExhaustSupply Installing External Supply Plenums Using the Supply Plenum ClipUsing the Uni-strut Installing the Supply Duct Collar to the Plenum External Supply Plenum Weights, Dimensions, and Supply RatesHanging the Back Supply Plenum Hanging the Hood Air DiffusersInstalling Enclosure Panels Installing End Skirts Installing Backsplash Panels Flat Backsplash PanelHood END Panel Installing Duct Collars Back View of the HoodExhaust Air Balancing Baffles Eabb Checking for BalanceTesting Hood Air Volume Baffle Filter Style Hoods Exhaust Balancing the Kitchen Exhaust SystemRotating Vane Anemometer Supply If Applicable 185 + 187.0 fpm High Velocity Cartridge Filters Exhaust Example282 fpm 423.0 cfm Volume with a rotating vane anemometer as follows 1042 4012 m3/hr Testing Hood Air Volume Short Circuit Hoods Supply Amerex Wiring Plan View PRMAnsul Wiring Plan View EquipmentOverall Wiring Plan View Basic Wiring Diagram Wiring by OthersWiring for Hood Switch Panels Circuit Diagrams OFFMaintenance Daily Maintenance Weekly MaintenancePeriodic Maintenance Condensate Hood Baffle InstallationGrease Grabber Filter Installation Grease Grabber Filter Cleaning Frequent MaintenanceFilter Washing Frequency Guide BestTroubleshooting Problem Cold air can be felt by the cook at the hood Replacement Parts Greenheck Registers Part Number Warranty

452413 specifications

The Greenheck Fan 452413 is a well-known model in the ventilation and air movement industry. Renowned for its durability and high performance, this fan is designed for commercial and industrial applications, ensuring optimal air flow and energy efficiency.

One of the standout features of the Greenheck Fan 452413 is its rugged construction. Made with robust materials that withstand harsh environments, this fan is built to last. Its housing is often constructed from galvanized steel, offering excellent resistance to rust and corrosion. This makes it suitable for various applications, from rooftop installations to indoor ventilations systems.

The fan's motor is another highlight. It typically includes high-efficiency motors that not only enhance performance but also help in reducing energy consumption. The Greenheck Fan 452413 often employs variable speed drives, allowing users to adjust the fan speed according to specific requirements. This flexibility facilitates energy savings and ensures optimal performance, especially in varying load conditions.

Noise reduction technology is also a focal point in the design of the Greenheck Fan 452413. The fan is engineered to operate quietly, which is crucial for environments where noise levels must be minimized, such as in residential areas, hospitals, or schools. The incorporation of innovative blade design reduces turbulence, resulting in lower operational noise without compromising airflow.

Another characteristic of the 452413 model is its ease of maintenance. Designed with user convenience in mind, the fan typically features access panels that allow for straightforward inspections and repairs. This design reduces downtime, ensuring that the ventilation system runs effectively without frequent interruptions.

Furthermore, Greenheck provides extensive customization options. The 452413 can be tailored to meet specific requirements, including size, airflow capacity, and additional features such as controls and accessories. This adaptability makes the fan a preferred choice across different sectors, including hospitality, manufacturing, and healthcare.

In summary, the Greenheck Fan 452413 stands out in the market due to its robust construction, energy-efficient motor technology, noise reduction capabilities, and ease of maintenance. Its versatility in customization further solidifies its position as a reliable solution for various ventilation needs, catering to both performance and efficiency in demanding environments. This fan embodies the quality and innovation that Greenheck is known for, ensuring a top-choice option for those seeking effective air movement solutions.