Installation instructions
11
Notes:
Flexible hoses can be used where the sited ambient temperature of the hose does not exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of the correct construction for the type of gas being used.
Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be identified by a either a red band or stripe on the rubber outer coating of the hose).
The hose should not be crushed or trapped or be in contact with sharp or abrasive edges. It should also not be subjected to corrosion by acidic cleansing agents.
To connect the gas supply:
1Fit the 1/2” BSP (female) connector (supplied with the cooker in a separate kit) to the gas inlet at the rear of the cooker interposing the gasket. Check the correct positioning of the connector as shown and always use two suitable spanners (Fig 6b).
2Connect the gas supply to the gas inlet at the rear of the cooker.
3 To avoid damage to the appliance gas rail
inlet pipe tighten the fittings using two suitable spanners (Fig. 6b).
4 Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks.
IMPORTANT!
Fig. 6a
Do not use a naked flame to test for leaks.
Cooker manifold
Manifold male pipe fitting
1/2” G cylindrical (ISO
Gasket (*)
1/2” G cylindrical (ISO
Connector (*)
1/2” BSP (female)
(*) Supplied with the appliance in a separate kit.
20 mm
20 mm
Fig. 6b