Fisher & Paykel CP-364GD, CP-486GD, CP-485GD, CP-364GL, CP-484GG, CP-366 From standard depth cabinet

Page 15

CABINET PREPARATION

6. Cut the openings for the following installation: ■ Standard counter top installation, see Fig. 8A ■ Deep counter or island installation, see Fig. 8B

NOTE:

If the deck is used, the sides or bottom of the cutout may be solid combustible or non-combustible material. If the bottom is solid, provide a 6" x 6" cutout in the left rear corner for the gas inlet and power cord clearance. See Fig. 6.

Front Frontprojprojectsoutwaoutward asshownown

from standard depth cabinet.

from standard depth cabinet.

Flush with cabinets

Front flush with cabinets; a minimum of 25-3/4”

Front flush with cabinets; a minimum

cabinet depth required

of 25 3/4" cabinet depth required

Fig. 4

unter-

Co

r-SunkScrews

Fig. 5

Cutout

 

6

6

 

Fig. 6

13

Image 15
Contents Models CP Series Professional GAS CooktopPage Please Retain this Manual for Future Reference Message to OUR CustomersTable of Contents Introduction Important Installation InformationSafety Practices and Precautions Safety Practices and Precautions Recommendations on HOOK-UP to GAS Supply CP Cooktop Models ModelsPlanning the Installation Recommended Installation Instruction Unpacking and HandlingMoving and Placing the Cooktop Anchoring the Cooktop Ventilation Requirements Standard Counter Island InstallationElectrical Gas Supply Cabinet PreparationFrom standard depth cabinet Cabinet face for installation with flush control panel Recommended Grounding Method Backguard InstallationElectrical Connections Electrical RequirementsLP GAS GAS HOOK-UPGAS Requirements Natural GASCooktop Burner Lighting Note Test and AdjustmentsThis Adjustment Section Applies to the Griddle Cooktop BurnersCleaning Exterior Surfaces GAS Supply Installer Final ChecklistGeneral ElectricalBefore YOU Call for Service HOW to Obtain ServiceThis Warranty does not Cover WarrantyLimited Warranty HOW Long does this Limited Warranty LAST?HOW to GET Service Commercial USENo Other Warranties Page Page Modèles Table DE Cuisson À GAZ Professionnelle DE Série CPVeuillez Conserver CE Manuel À Titre DE Référence Lintention DE NOS ClientsEssai ET Réglages Informations Importantes Concernant Linstallation Mesures DE Sécurité ET DE Précaution Mesures DE Sécurité ET DE Précaution Remarque Recommandations Concernant LE Branchement DU GAZModèles DE Tables DE Cuisson CP 36 PO Modèles DE Tables DE Cuisson CP 48 PONuméro de modèle Planification DE LinstallationInstructions Concernant Linstallation Recommandée Déplacement ET Placement DE LA Table DE CuissonDéballage ET Manipulation Ancrage DE LA Table DE Cuisson Exigences EN Matière DE Ventilation Appareil de RecommandationsHotte de 48 po de largeur min Hotte de 36 po de largeur min Préparation DES Armoires25 3/465,4cabinetcm 25d3/4eppoth required 67,3 cm 26-1/2 po Niveau du comptoir Connexions Électriques Installation DU DosseretMéthode DE Mise À LA Terre Recommandée Connexions ÉlectriquesBranchement DU GAZ Branchement DU GAZExigences Concernant LE GAZ GAZ NaturelTable DE Cuisson Brûleurs Essai ET RéglagesNettoyage DES Surfaces Extérieures Alimentation EN GAZ Liste DE Contrôle Finale DE LinstallateurGénéralités ÉLECTRIQUE/CARACTÉRISTIQUES ÉlectriquesPour Lobtention DE Service Avant Dappeler LE Service TechniqueSI LES Brûleurs DE LA Table DE Cuisson NE Sallument PAS NE Sont PAS Couverts PAR LA Garantie GarantieFisher & Paykel Sengage À Quelle EST LA Durée DE Cette Garantie LIMITÉE?Pour Obtenir DES Réparations Utilisation CommercialeAucune Autre Garantie Remarque