Fisher & Paykel CP-486GD Installer Final Checklist, General, Electrical, GAS Supply, Operation

Page 21

INSTALLER FINAL CHECKLIST

GENERAL

Placement of unit.

Specified clearance maintained to cabinet surfaces.

Unit Level - front to back, side to side.

All packaging material and tie straps removed, drip pans clean and empty.

Backguard attached if there is less than 12" clearance above the cooking surface to combustibles behind unit.

Radiant tray placed in grill unit (if equipped). The two grill racks in place.

ELECTRICAL

Receptacle with 15 ampere over-current protection is provided for service cord connection.

Adequate ground connection.

GAS SUPPLY

Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is compatible with range model, and sufficient pressure is available (see gas requirements pg. 16).

The pressure regulator which is connected to the manifold is set for 5.0” W.C. for natural gas or 10.0” W.C. for LP.

Manual gas shut-off valve installed in an accessible location.

Unit tested and free of gas leaks.

OPERATION

All internal packing materials removed. Check below grate, pans and drip drawers.

If used on LP gas, verify that pressure regulator, orifice hoods, air shutters, and valve jets have been set for use with LP gas.

Grill compartment seated and does not rock (if equipped).

Bezels centered on burner knobs and knobs turn freely.

Each burner lights satisfactorily, both individually and with other burners operating at the same time.

Flame adjustment for 3/8” soft blue cone made on ports of each top burner, low flame adjustment verified.

Griddle is level and does not rock (if equipped).

Drip trays are properly in place and pull out freely (if equipped).

Burner grates correctly positioned, level, and do not rock.

Griddle flame (see page 17).

Grill flame (see page 17).

Cooktop burner flame (see page 17).

19

Image 21
Contents Models CP Series Professional GAS CooktopPage Please Retain this Manual for Future Reference Message to OUR CustomersTable of Contents Introduction Important Installation InformationSafety Practices and Precautions Safety Practices and Precautions Recommendations on HOOK-UP to GAS Supply CP Cooktop Models ModelsPlanning the Installation Recommended Installation Instruction Unpacking and HandlingMoving and Placing the Cooktop Anchoring the Cooktop Ventilation Requirements Standard Counter Island InstallationElectrical Gas Supply Cabinet PreparationFrom standard depth cabinet Cabinet face for installation with flush control panel Electrical Connections Backguard InstallationElectrical Requirements Recommended Grounding MethodGAS Requirements GAS HOOK-UPNatural GAS LP GASThis Adjustment Section Applies to the Griddle Test and AdjustmentsCooktop Burners Cooktop Burner Lighting NoteCleaning Exterior Surfaces General Installer Final ChecklistElectrical GAS SupplyBefore YOU Call for Service HOW to Obtain ServiceLimited Warranty WarrantyHOW Long does this Limited Warranty LAST? This Warranty does not CoverHOW to GET Service Commercial USENo Other Warranties Page Page Modèles Table DE Cuisson À GAZ Professionnelle DE Série CPVeuillez Conserver CE Manuel À Titre DE Référence Lintention DE NOS ClientsEssai ET Réglages Informations Importantes Concernant Linstallation Mesures DE Sécurité ET DE Précaution Mesures DE Sécurité ET DE Précaution Remarque Recommandations Concernant LE Branchement DU GAZModèles DE Tables DE Cuisson CP 36 PO Modèles DE Tables DE Cuisson CP 48 PONuméro de modèle Planification DE LinstallationInstructions Concernant Linstallation Recommandée Déplacement ET Placement DE LA Table DE CuissonDéballage ET Manipulation Ancrage DE LA Table DE Cuisson Exigences EN Matière DE Ventilation Appareil de RecommandationsHotte de 48 po de largeur min Hotte de 36 po de largeur min Préparation DES Armoires25 3/465,4cabinetcm 25d3/4eppoth required 67,3 cm 26-1/2 po Niveau du comptoir Méthode DE Mise À LA Terre Recommandée Installation DU DosseretConnexions Électriques Connexions ÉlectriquesExigences Concernant LE GAZ Branchement DU GAZGAZ Naturel Branchement DU GAZTable DE Cuisson Brûleurs Essai ET RéglagesNettoyage DES Surfaces Extérieures Généralités Liste DE Contrôle Finale DE LinstallateurÉLECTRIQUE/CARACTÉRISTIQUES Électriques Alimentation EN GAZPour Lobtention DE Service Avant Dappeler LE Service TechniqueSI LES Brûleurs DE LA Table DE Cuisson NE Sallument PAS Fisher & Paykel Sengage À GarantieQuelle EST LA Durée DE Cette Garantie LIMITÉE? NE Sont PAS Couverts PAR LA GarantiePour Obtenir DES Réparations Utilisation CommercialeAucune Autre Garantie Remarque