18
Installation instructions
Rear wall
Rear wall
700 mm
| Suggested area for gas |
|
| Suggested area for |
|
| mains connection |
|
mm | gas mains connection |
|
|
| |
200 | Figure 12 Gas mains connection area | |
|
Replacement of burner injectors
If the injectors are not supplied, contact the Fisher & Paykel Authorised Service Centre. Select the injectors to be replaced according to the “Table for the choice of the injectors”.
To replace the injectors
Remove pan supports and burners from the cooktop. Using a wrench substitute the nozzle injectors with those most suitable for the kind of gas for which it is to
be used. The burners are designed so that adjustment of primary air is not required.
Injector
Injector
Figure 13 Auxiliary, | Figure 14 Triple ring wok burner |
|
|
|
|