HOOD CONTROL BUTTONS

Off

Pressing button once turns ventilator off and resets control.

Fan Speed

Pressing button once, from an off state, turns the ventilator on low. Each successive press of the button increases the fan speed until high then the fan cycles back to the low speed.

The LEDs above this button indicate the current fan speed. When the fan is on, the corresponding LED is illuminated.

1 – Low

2 – Medium

3 – High

Delay Shut Off

Press to turn fan on high for 10 minutes.

If the ventilator is off when the delay button is pressed, the ventilator will turn on to the high speed setting for 10 minutes. At the end of the cycle the ventilator will turn off.

If the ventilator is on when the delay button is pressed, the ventilator runs for 10 minutes at the current speed then turns off.

During a timed period, the LED above the Delay Shut Off button is illuminated.

To interrupt a timed period, press Fan Speed or Off button.

Clean Filter Reminder

After 40 hours of operation, the clean filter re- minder LED above this button will illuminate indicat- ing that the filters need to be cleaned. When this indicator illuminates, clean the filters as instructed on page 6. After cleaning, press this button for 3 seconds to reset the 40-hour period and turn the LED off.

Light On/Dim/Off

This button controls the halogen lighting. The first press turns the lights on. A second press dims the lights. A third press turns the lights off.

Heat Lamp

The buttons marked “L” and “R” independently control the left and right infrared heating lamps, turning the lights on or off.

Heat Sensor

Note: The heat sensor features listed below are not available when the hood is installed with the remote control accessory.

Your hood is equipped with a heat sensor that will turn the blower to Low speed if excessive heat occurs above the cooking surfaces.

1.If the blower is off – it turns the blower on to low speed.

2.If the blower is already on any speed selection, no speed change will occur.

When the temperature level on the hood drops to normal, the blower will return to its original setting.

Over Temperature Condition - The high tempera- ture sensor protects the hood from high tempera- tures which may damage components. The control is set to activate at 161° F (72° C) and reset at 140°F (60° C). When activated, the ventilator will turn on low and the corresponding LED will blink, indicating an over temperature condition.

While the high temperature sensor is activated, the blower speed can be changed or turned off. If the blower is turned off, the corresponding LED will blink. Light controls will remain operational. When the control sensor reaches 140°F (60° C), a reset will occur. During reset, the control will revert back to the operational state prior to the high temperature condition.

High Temperature Fault Condition - The circuit is equipped with an alarm indicating that the heat sensor protection is not working, due to a damaged sensor. In the case of this extreme condition, the three speed indicator LEDs will start blinking. All the controls will be operational except for the speed indicators.

PAGE 5

Image 5
Contents Read and Save These Instructions Care and USE ManualTable of Contents Retain this manual for future reference Important Safety InstructionsHood Control Panel Operating the HoodHood Control Buttons To Clean Hood Surface Care and CleaningTo Clean Filters and Troughs To Remove Filters and Grease TroughsHalogen Light Replacement MaintenanceHeat Lamp Replacement LightsStatement of Limited Product Warranty Page Table DES Matières Avertissement Instructions DE Sécurité ImportantesConserver ce guide à des fins de références Panneau de contrôle pour hotte Fonctionnement DE LA HotteTouches DE Contrôle DE LA Hotte Nettoyage de la surface Entretien ET NettoyageNettoyage des filtres et godets Retrait des filtres et godets à graisseRemplacement de l’ampoule réchaud Remplacement de l’ampoule halogèneEntretien ÉclairageÉnoncédegarantielimitéeduproduit Page Contenido Atención Instrucciones Importante DE SeguridadGuarde este manual para consultarlo en el futuro Panel de Control para las Campanas Operar LA CampanaBotones DE Control DE LA Campana Limpiar la Superficie de la Campana Cuidado Y LimpiezaLimpiar los Filtros y Colectores Para Quitar los Filtros y Colectores de GrasaLámparas MantenimientoReemplazar la Lámpara de Halógeno Reemplazar la Lámpara de CalentamientoDeclaratoria DE Garantía Limitada DEL Producto