Cleveland Range 24CGA10.2 manual SteamCraft Gemini TM, Cleveland Range Inc, MODEL 24-CGA-10.2

Page 11
SteamCraft ® Gemini TM 10

SteamCraft ® Gemini TM 10

TWO COMPARTMENT FLOOR MODEL DESIGN PRESSURELESS CONVECTION STEAMERTWIN, INDEPENDENT GAS-FIRED GENERATORS

Cleveland Standard Features

Cooking Capacity for up to ten 12˝ x 20˝ x 2 1/2˝ deep Cafeteria Pans, five each compartment.

Totally independent cooking compartments, each has its' own generator, gas valve and water level controls - no shared components

Exclusive High Efficiency Gas Power Burner (forced air) Generator: Produces more steam for faster cooking while lowering operating costs (72M BTU's per compartment)

Easy Access Cleaning Port: Each generator has a deliming port located on the outside, top of the unit

Generator Cleaning Light for each compartment warns the operator to delime generator

Instant Steam Standby Mode: Holds generator at a steaming temperature, allows unit to start cooking instantly

Each compartment has one, 60-Minute Electro-Mechanical Timer with load compensating feature. Manual Bypass Switch for constant steaming.

Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator

Exclusive Two-Piece Compartment door: Slammable, self-adjusting door provides and airtight seal, reversable door gasket for extended life

Exclusive Gemini Drain/Power Control System: Simple, reliable 1/2" ball valve style drain automatically turns power

ON/OFF

Exclusive Brass Steam Jets distribute even-high velocity steam throughout cooking compartment for faster cooking times

Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit

6˝ Stainless Steel Adjustable Legs with Flanged Feet

Approvals: CSA (AGA, CSA) and U.L/NSF#4

Compartment Steam Shut-Off Switch (SCS)

Options & Accessories

Electronic Timer with Compensating Feature (ETC)

On/Off Steam Switch Controls, no timer (MC)

Cleveland Range Inc.

MODEL: 24-CGA-10.2

ITEM NUMBER __________________________________________

JOB NAME / NUMBER __________________________________

Short Form Specifications

Shall be Two Compartments, Cleveland Convection Steamer series SteamCraftGeminiTM 10, Model 24-CGA-10.2, Twin Gas Atmospheric Steam Generator, 72M BTU"s input per compartment. Independent steam generator, gas valve and water level control system. Automatic Generator Blowdown. Steam Generator with Automatic Water Fill on start up. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Two-piece free- floating compartment door. Type 430 Stainless Steel exterior and cook- ing compartments. Pullout service drawer for controls and Gemini Drain/Power Control System. Exclusive Cold Water Condenser design. Choice of Compartment Controls. Manual

Propane Gas (PG)

Dissolve ® Descale Solution, 6 one gallon container w/quart markings (106174)

Water Filters

SECT. IV PAGE 13 0402

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Ph: 1-216-481-4900 Fx: 1-216-481-3782

Visit our Web Site at www.clevelandrange.com

Image 11
Contents Phone 216 481-4900 1-800-338-2204 Fax Parts ManualFloor type Gas Convection Steamer Series SteamCraft Model 24CGA10.2 1333 East 179th Street Cleveland, OhioPage Page Page Page Page Page Page Page Statement of Responsibilities SteamCraft Gemini TM Cleveland Standard FeaturesOptions & Accessories Short Form SpecificationsWATER QUALITY REQUIREMENTS Each Compartment has capacity forFive, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical TimerThe “Sure Cook” light is de-energized 8. When the on/off lever is turned offThe red “Power On” indicator light is de-energized The main burner is ignited and the water heated to steamRESET SWITCH GEMINI GAS - MECHANICAL TIMERPRP11-4 GEMINI GAS / MECHANICAL TIMERCOMPONENT PARTS LIST P300095 CGEMINI GAS - ELECTRONIC TIMER RED WHT/RED BLK WHT GEMINI GAS / ELECTRONIC TIMERCOMPONENT PARTS LIST P300096 CSteamer wont No fill PROBLEM 24CGA6 24CGA10.2Steamer wont steam with handle in on position Steamer wont steamSteamer wont fill Steamer wont fill with the handle in the on positionSteamer wont 24CGA624CGA10.2 PROBLEMSTART PROBLEM 24CGA6, 24CGA10.2Electronic timer displays PAUS and wont count down PROBLEM 24CGA6, 24CGA10.2 Steam leaks around the door10. When the timer times out after 20 minutes turn the power Off Descaling Procedure-SteamCraft Ultra and Gemini Series2. Turn the unit power back On 3. Select Timed with the Timed/Manual switch