Cleveland Range PROBLEM 24CGA6, 24CGA10.2, Electronic timer displays PAUS and wont count down

Page 22
PROBLEM:

PROBLEM:

24CGA6, 24CGA10.2

Electronic timer displays "PAUS" and won't count down

START

Is steam heating the cooking cabinetabove 192 degrees (the set temp of the thermo-switch)?

Yes

See

No Electronic timer displays "PAUS" and won't count down Steamer won't steam

Replace the

Yes

Does the timer count down when

No

Replace the

thermo-switch

the thermo-switch

is bypassed?

electronic timer

PROBLEM:

24CGA6, 24CGA10.2

Steam leaks around the door.

START

Is COLD water supplied to the steamer?

Yes

Is the door gasket

physically damaged?

Yes

Turn over the gasket or replace it.

No

No

Supply cold water (35-60 PSI) to the steamer.

Is the door out of

alignment?

Yes

Replace the door bearings and pins.

No

Is the drain obstructed?

Yes

Remove the obstruction

No

Is there 120 VAC

 

 

 

Replace the

across the coil of

No

 

wiring to the

the condensate

 

condensate

 

 

 

solenoid?

 

 

 

solenoid.

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Replace the

Is the solenoid

 

 

 

No

 

 

condensate

opening?

 

 

 

 

solenoid.

 

 

 

 

 

 

 

 

 

Yes

Replace the

condensate spray

nozzle

Image 22
Contents 1333 East 179th Street Cleveland, Ohio Parts ManualFloor type Gas Convection Steamer Series SteamCraft Model 24CGA10.2 Phone 216 481-4900 1-800-338-2204 FaxPage Page Page Page Page Page Page Page Statement of Responsibilities Short Form Specifications Cleveland Standard FeaturesOptions & Accessories SteamCraft Gemini TMFive, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans Each Compartment has capacity forWATER QUALITY REQUIREMENTS Mechanical Timer CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONSThe main burner is ignited and the water heated to steam 8. When the on/off lever is turned offThe red “Power On” indicator light is de-energized The “Sure Cook” light is de-energizedGEMINI GAS - MECHANICAL TIMER RESET SWITCHP300095 C GEMINI GAS / MECHANICAL TIMERCOMPONENT PARTS LIST PRP11-4GEMINI GAS - ELECTRONIC TIMER P300096 C GEMINI GAS / ELECTRONIC TIMERCOMPONENT PARTS LIST RED WHT/RED BLK WHTSteamer wont steam PROBLEM 24CGA6 24CGA10.2Steamer wont steam with handle in on position Steamer wont No fillSteamer wont fill with the handle in the on position Steamer wont fillPROBLEM 24CGA624CGA10.2 Steamer wontPROBLEM 24CGA6, 24CGA10.2 Steam leaks around the door PROBLEM 24CGA6, 24CGA10.2Electronic timer displays PAUS and wont count down START3. Select Timed with the Timed/Manual switch Descaling Procedure-SteamCraft Ultra and Gemini Series2. Turn the unit power back On 10. When the timer times out after 20 minutes turn the power Off