Cleveland Range manual CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONS

Page 13

CLEVELAND RANGE GEMINI 24CGA 6.2

AND 24CGA10.2

SEQUENCE OF OPERATIONS

Mechanical Timer

Starting with the timed manual switch in the timed position, and no time on the timer.

1.To turn the unit on, turn the ON/OFF lever clockwise to the ON position

This mechanically closes the drain.

The red “Power On” indicator is energized.

115 VAC is sent through the timer to the three-second timer, which activates the buzzer for three seconds.

115 VAC is sent through the normally closed R1 contacts to the fan motor, turning it

ON

115 VAC is sent to H and N of the water level board

2.With the water level board energized and no water in the generator

115 VAC is sent from the FILL terminal to the fill solenoid.

The fill solenoid opens and the generator fills.

3.The water fills to the low probe shorting it to ground

115 VAC is sent from the HEAT terminal to the timed manual switch.

115 VAC is sent through the high limit to the primary of the 24VAC transformer.

The water continues to fill until the water level reaches the high probe then 115 VAC is removed from the FILL terminal and the fill solenoid is turned off

4.24VAC is sent to the ignition module.

Spark is sent to the igniter.

24VAC is sent to the pilot coil of the gas valve and the coil of the R1 relay.

The normally closed R1 contacts open, turning off the fan

The pilot lights, which acts as a standby heater. When the pilot is ignited and the module detects 1.0 micro amps DC, the MV terminal on the module is energized it remains in this standby heat mode until a cooking compartment is turned “ON” (see step 5).

5.When the timed/manual switch is in the timed position and time is on the timer or the timed manual switch is set to the manual position:

115 VAC is sent to the clean light timer.

When the clean light timer times down 115 VAC is sent to the clean light switch.

When the clean light switch is depressed the timer is reset.

115 VAC is sent from the compartment timer through the door switch to the normally closed contacts of the compartment thermostat and R2 relay coil.

• The “Sure Cook” light is energized.

115 VAC is also sent from the door switch through the now closed contacts of the R1 relay to the fan motor.

The fan motor turns ON, and comes up to speed.

Image 13
Contents Floor type Gas Convection Steamer Series SteamCraft Model 24CGA10.2 Parts Manual1333 East 179th Street Cleveland, Ohio Phone 216 481-4900 1-800-338-2204 FaxPage Page Page Page Page Page Page Page Statement of Responsibilities Options & Accessories Cleveland Standard FeaturesShort Form Specifications SteamCraft Gemini TMFive, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans Each Compartment has capacity forWATER QUALITY REQUIREMENTS CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical TimerThe red “Power On” indicator light is de-energized 8. When the on/off lever is turned offThe main burner is ignited and the water heated to steam The “Sure Cook” light is de-energizedRESET SWITCH GEMINI GAS - MECHANICAL TIMERCOMPONENT PARTS LIST GEMINI GAS / MECHANICAL TIMERP300095 C PRP11-4GEMINI GAS - ELECTRONIC TIMER COMPONENT PARTS LIST GEMINI GAS / ELECTRONIC TIMERP300096 C RED WHT/RED BLK WHTSteamer wont steam with handle in on position PROBLEM 24CGA6 24CGA10.2Steamer wont steam Steamer wont No fillSteamer wont fill Steamer wont fill with the handle in the on position24CGA10.2 24CGA6PROBLEM Steamer wontElectronic timer displays PAUS and wont count down PROBLEM 24CGA6, 24CGA10.2PROBLEM 24CGA6, 24CGA10.2 Steam leaks around the door START2. Turn the unit power back On Descaling Procedure-SteamCraft Ultra and Gemini Series3. Select Timed with the Timed/Manual switch 10. When the timer times out after 20 minutes turn the power Off