Cleveland Range PROBLEM 24CGA6 24CGA10.2, Steamer wont fill with the handle in the on position

Page 20
Steamer won't fill with the handle in the on position

PROBLEM:

24CGA6

24CGA10.2

Steamer won't fill with the handle in the on position

Steamer won't

fill

Is there power to the steamer?

Yes

Is there water to

the steamer?

Yes

Is there 120 VAC

between the

terminals H and N on the watr level board?

Yes

Is there 120 VAC between terminals Fill and N on the water board?

Yes

No

No

No

No

Connect

power to the steamer

Supply

water to the

steamer.

Adjust or replace on/off micro switch

With the wire

removed from the HI terminal on the water level board, is there 120 VAC between terminals Fill and N?

Yes

Replace the

No

water level

board.

Adjust or

replace the on/

No

Is there 120 VAC across the coil of

Is there debris on the HI probe in the

No

Replace the

off micro switch

the fill solenoid?

Yes

probe assy?

Yes

wire to the HI

probe.

Replace the fill

solenoid.

Clean or

replace the drain valve.

No

No

Is water leaving

 

the fill solenoid?

 

Yes

Yes

Does the manual

 

drain valve close

 

completely?

 

Clean or

replace the probe assy.

Image 20
Contents Parts Manual Floor type Gas Convection Steamer Series SteamCraft Model 24CGA10.21333 East 179th Street Cleveland, Ohio Phone 216 481-4900 1-800-338-2204 FaxPage Page Page Page Page Page Page Page Statement of Responsibilities Cleveland Standard Features Options & AccessoriesShort Form Specifications SteamCraft Gemini TMWATER QUALITY REQUIREMENTS Each Compartment has capacity forFive, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans Mechanical Timer CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONS8. When the on/off lever is turned off The red “Power On” indicator light is de-energizedThe main burner is ignited and the water heated to steam The “Sure Cook” light is de-energizedGEMINI GAS - MECHANICAL TIMER RESET SWITCHGEMINI GAS / MECHANICAL TIMER COMPONENT PARTS LISTP300095 C PRP11-4GEMINI GAS - ELECTRONIC TIMER GEMINI GAS / ELECTRONIC TIMER COMPONENT PARTS LISTP300096 C RED WHT/RED BLK WHTPROBLEM 24CGA6 24CGA10.2 Steamer wont steam with handle in on positionSteamer wont steam Steamer wont No fillSteamer wont fill with the handle in the on position Steamer wont fill24CGA6 24CGA10.2PROBLEM Steamer wontPROBLEM 24CGA6, 24CGA10.2 Electronic timer displays PAUS and wont count downPROBLEM 24CGA6, 24CGA10.2 Steam leaks around the door STARTDescaling Procedure-SteamCraft Ultra and Gemini Series 2. Turn the unit power back On3. Select Timed with the Timed/Manual switch 10. When the timer times out after 20 minutes turn the power Off