PROBLEM:
24CGA6
24CGA10.2
Steamer won't fill with the handle in the on position
Steamer won't
fill
Is there power to the steamer?
Yes
Is there water to
the steamer?
Yes
Is there 120 VAC
between the
terminals H and N on the watr level board?
Yes
Is there 120 VAC between terminals Fill and N on the water board?
Yes
No
No
No
No
Connect
power to the steamer
Supply
water to the
steamer.
Adjust or replace on/off micro switch
With the wire
removed from the HI terminal on the water level board, is there 120 VAC between terminals Fill and N?
Yes
Replace the
No
water level
board.
Adjust or
replace the on/
No
Is there 120 VAC across the coil of
Is there debris on the HI probe in the
No
Replace the
off micro switch
the fill solenoid?
Yes
probe assy?
Yes
wire to the HI
probe.
Replace the fill
solenoid.
Clean or
replace the drain valve.
No
No
Is water leaving |
|
the fill solenoid? |
|
Yes | Yes |
Does the manual |
|
drain valve close |
|
completely? |
|
Clean or
replace the probe assy.