Cleveland Range manual PROBLEM 24CGA6 24CGA10.2, Steamer wont steam with handle in on position

Page 19
PROBLEM:

PROBLEM:

24CGA6

24CGA10.2

Steamer won't

steam with handle

in on position

Steamer won't

steam

See

Steamer won't Steamer won't No fill.

See

Steamer won't Steamer won't  No fill. No ignite

Is the red light on? Steamer won't  No ignite

Yes

Is there water in the sight glass?

Yes

Has the pilot ignited?

Yes

No

Is there power to the steamer?

Yes

Adjust or replace the on/off micro switch

No

Connect power

to steamer.

 

Replace the

wiring to the No switch

Replace the

No

switch

 

Is there power to the Timed/Manual switch?

Yes

Is there power

from the Timed/ Manual switch?

Yes

Does the steamer

steam with the

door switch bypassed?

Yes

Replace the door switch

No

No

Does the steamer steam in manual mode?

Yes

Replace the timer

Is there 120 VAC to the R2 relay?

Yes

Is the fan turning?

Yes

Is there 24 VAC to the main coil of the gas valve?

No

No

No

Replace the wiring to relay

Is there 120 VAC

to the fan?

Yes

Replace the fan

Check the

No

R1 relay

Yes

Replace the

gas valve?

Does the coil to

the main gas valve get 24 VAC when the fan prover switch is bypassed?

Yes

Replace the the fan prover switch.

Replace the R2

No

relay.

Image 19
Contents Phone 216 481-4900 1-800-338-2204 Fax Parts ManualFloor type Gas Convection Steamer Series SteamCraft Model 24CGA10.2 1333 East 179th Street Cleveland, OhioPage Page Page Page Page Page Page Page Statement of Responsibilities SteamCraft Gemini TM Cleveland Standard FeaturesOptions & Accessories Short Form SpecificationsFive, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans Each Compartment has capacity forWATER QUALITY REQUIREMENTS CLEVELAND RANGE GEMINI 24CGA AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical TimerThe “Sure Cook” light is de-energized 8. When the on/off lever is turned offThe red “Power On” indicator light is de-energized The main burner is ignited and the water heated to steamRESET SWITCH GEMINI GAS - MECHANICAL TIMERPRP11-4 GEMINI GAS / MECHANICAL TIMERCOMPONENT PARTS LIST P300095 CGEMINI GAS - ELECTRONIC TIMER RED WHT/RED BLK WHT GEMINI GAS / ELECTRONIC TIMERCOMPONENT PARTS LIST P300096 CSteamer wont No fill PROBLEM 24CGA6 24CGA10.2Steamer wont steam with handle in on position Steamer wont steamSteamer wont fill Steamer wont fill with the handle in the on positionSteamer wont 24CGA624CGA10.2 PROBLEMSTART PROBLEM 24CGA6, 24CGA10.2Electronic timer displays PAUS and wont count down PROBLEM 24CGA6, 24CGA10.2 Steam leaks around the door10. When the timer times out after 20 minutes turn the power Off Descaling Procedure-SteamCraft Ultra and Gemini Series2. Turn the unit power back On 3. Select Timed with the Timed/Manual switch