Cleveland Range SD- 650, SD-760- K12, SD-760-K20, SD-1600-K 12 12, SD-1600-K 12 20 manual Installation

Page 3

INSTALLATION

GENERAL

Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage.

This unit is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/Ntl.Bd., CSA, ETL, CE, and others. Many local codes exist, and it is the responsibility of the owner/installer to comply with these codes.

INSPECTION

Before uncrating, visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions.

SHIPPING DAMAGE

INSTRUCTIONS

If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim.

1.Write down a description of the damage or the reason for suspecting damage as soon as it is discovered. This will help in filling out the claim forms later. If possible, take a polaroid picture.

2.As soon as damage is discovered or suspected, notify the carrier that delivered the shipment.

3.Arrange for the carrier's representative to examine the damage.

4.Fill out all carrier claims forms and have the examining carrier sign and date each form.

CLEARANCE REQUIREMENTS

The first installation step is to refer to the SPECIFICATION DRAWINGS at the back of this manual in order to determine the exact location of the kettle.

CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURFACES:

 

RIGHT

LEFT

BACK

KDT-1-T

4"

0"

0"

KDT-3-T & KDT-6-T

4"

4"

1"

KDT-12-T & KDT-20-T

4"

4"

1.75"

Note: For SD Stands (with or without kettles) zero clearance is required on the sides and back.

KETTLES

Table-top models must be positioned on a firm stand or existing counter top and secured in place. An optional modular cabinet base (SD Stand), with level-adjustable legs is available .

1.Make two 1" holes for the kettle legs.

 

DRILL TWO

A

 

1" HOLES

8 1/8"

 

KDT-1-T

 

KDT-3-T

10"

 

KDT-6-T

12"

 

KDT-12-T

19 1/2"

 

KDT-20-T

23 3/4"

 

A

 

2. Remove the leg mounting

 

 

locknuts and washers from

 

 

the kettle's legs.

 

3. Install the legs into the two

 

 

1" holes.

 

4.

Position washers as

 

 

illustrated and secure

 

 

the kettle to its' base by

 

 

refastening the locknut

 

 

from underneath the

 

 

cabinet or countertop.

 

5. Once the kettle is secure,

 

 

screw the tilt handle into

 

 

the mounting block welded

 

 

to the side of the kettle.

 

6.

Install service requirements

 

 

as required.

 

KETTLES c/w SD STAND

1.Place unit in desired location.

2.Place a carpenter's level on the kettle rim and level the stand using the level adjustable feet.

3.Install service requirements as required.

1

Image 3
Contents Operators Manual Table of Contents Installation Potable Water Final Installation CheckSchematics SteamOperation Operating InstructionsCare and Cleaning Cleaning InstructionsService Parts Item no Description QTY For SD Stands Plumbing AssemblyFront Access Panels Plumbing Assembly for SD StandsFaucet Assemblies Item no Marine Lock MaintenancePressure Relief Valve Testing Procedure WarrantyProblem Troubleshooting GuideKDT-1-T Specification DrawingsRight 4 Left 4 Back KDT-3-T & KDT-6-TKDT-12-T & KDT-20-T SD Stands with