STEAM

CONDENSATE (Kettles c/w SD Stands)

All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made.

Generally, kettles require 1/2" i.p.s. pipe, 10-45 psi steam pressure. If the steam supply pressure exceeds 45 psi, a pressure reducing valve is required. The steam inlet is at the right side of the kettle, as seen from the front.

CONDENSATE (Kettles without SD Stands)

Maximum pressure rating on table-top kettles is 50psi. It is highly recommended that a pressure relief valve equal to or less than this pressure be installed on the incoming steam line close to the kettle.

A steam condensate trap must be plumbed to a drain, using minimum 1/2" NPT plumbing. The condensate line is limited to a maximum rise of 10 feet in order for the steam pressure to adequately force the condensate through the plumbing. Any higher rise requires a pump.

If the steam boiler to which this kettle is installed has a condensate return (closed loop system), a 1/2" steam strainer, a 1/2" steam trap, and a 1/2" check valve must be installed on the output (condensate) side of the kettle.

The stand comes factory plumbed so the condensate is connected to the stands drain manifold.

POTABLE WATER

The water faucet (optional on kettles purchased without SD stands) with swing spout, requires 1/2 inch O.D. copper tube plumbing for hot or cold water supplies to the faucet (SPK - cold water connection only, DPK - hot and cold water connection).

FINAL INSTALLATION CHECK

1.Partially fill the kettle with water.

2.Slowly turn the steam supply valve's knob to the open position.

3.Release the safety valve, ensuring that the steam escapes freely. Stay clear of steam exhaust when releasing the safety valve.

4.Observe that the water in the kettle comes to a boil.

5.Close the steam supply valve.

6.Drain off the water by tilting the kettle.

RECOMMENDED PIPING

 

 

 

KETTLES

SCHEMATICS

 

 

 

 

 

(all service connections shown supplied by others)

 

 

 

 

 

 

 

 

MANUAL

 

 

 

 

 

STEAM

 

 

 

 

 

VALVE

 

 

CONDENSATE RETURN

 

 

 

TO DRAIN OR BOILER

 

 

 

 

 

CONDENSATE LINE

 

 

 

 

 

UNION

CHECK

 

 

 

STEAM

KETTLES c/w

STEAM

STRAINER

 

VALVE

TRAP

 

IN

 

 

STRAINER

 

 

SD STANDS

 

 

 

 

 

 

PRESSURE

UNION

 

 

 

REDUCING

BALL

 

 

 

VALVE

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

STEAM

 

 

 

 

 

IN

 

 

STRAINER

UNION

BALL

 

 

 

 

 

VALVE

 

 

 

TO DRAIN (CONDENSATE RETURN PLUMBED TO 1 1/2" DRAIN MANIFOLD)

 

 

 

 

2

 

 

 

Image 4
Contents Operators Manual Table of Contents Installation Final Installation Check SchematicsSteam Potable WaterOperating Instructions OperationCleaning Instructions Care and CleaningService Parts Item no Description QTY Plumbing Assembly For SD StandsPlumbing Assembly for SD Stands Front Access PanelsFaucet Assemblies Item no Maintenance Pressure Relief Valve Testing ProcedureWarranty Marine LockTroubleshooting Guide ProblemSpecification Drawings KDT-1-TKDT-3-T & KDT-6-T Right 4 Left 4 BackKDT-12-T & KDT-20-T SD Stands with