Mounting the hood body

Screw the two screws 12d supplied onto the brackets 7.1.

Hook the hood body onto the bracket 7.1, centring it around the vertical line.

Use the adjusting screws 12d underneath the hood to level the hood body.

12.d

7.1

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125 mm, the choice of which is left to the installer.

To install a ø 125 mm air exhaust connection, insert the re- ducer flange 9 on the hood body air outlet and the adapting ring ø120-125 10 on the reducer flange.

Fix the pipe in position using sufficient pipe clamps (not sup- plied).

Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

Push fit the air outlet fitting 15 onto the air outlet of the hood body.

Ensure that the activated charcoal filters have been inserted.

ø 150 ø 125

9

10

 

15

EN

 

1

 

13

Image 13
Contents Page Index IndiceSommaire InhaltsverzeichnisConsigli E Suggerimenti InstallazioneUSO ManutenzioneCaratteristiche Foratura Parete e Fissaggio Staffe InstallazioneFondale Opzionale Connessioni Montaggio Corpo CappaUscita Aria Versione Aspirante Uscita Aria Versione FiltranteConnessione Elettrica Montaggio CaminoCamino superiore Camino inferioreUSO Filtri antigrasso ManutenzioneFiltri antiodore al Carbone attivo Versione Filtrante IlluminazioneMaintenance InstallationRecommendations and Suggestions USECharacteristics Wall drilling and bracket fixing InstallationRear Panel Optional Connections Mounting the hood bodyDucted Version AIR Exhaust System Recirculation Version AIR OutletElectrical Connection Chimney assemblyUpper chimney section Lower chimney sectionUSE Grease filters MaintenanceActivated charcoal filter Recirculation version LightingUtilisation Conseils ET SuggestionsEntretien Caracteristiques Fixation Embase SI Fournie Perçage Paroi et Fixation BridesConnexions Montage Corps HotteSortie DE Lair EN Version Evacuation Sortie AIR Version FiltranteBranchement Electrique Montage CheminéeCheminée supérieure Cheminée inférieureUtilisation Filtres anti-graisse EntretienFiltre anti-odeur Version filtrante EclairageMontage Empfehlungen UND HinweiseBedienung WartungCharakteristiken Rückwandpaneel Option MontageAnschlüsse Montage des HaubenkörpersLuftaustritt BEI DER Absaugversion Anschluss in UmluftversionElektroanschluss KaminmontageOberer Kaminteil Unterer KaminteilBedienung Fettfilter WartungGeruchsfilter Umluftversion BeleuchtungAdviezen EN Suggesties InstallatieGebruik OnderhoudEigenschappen Boren van gaten in de wand en bevestiging van de beugels InstallatieMuurplaat Optioneel Aansluitingen Montage van de WasemkapLuchtuitgang Aanzuigende Uitvoering Luchtuitlaat FilterversieElektrische Aansluiting Montage van de schouwBovenstuk van de schouw Onderstuk van de schouwGebruik Vetfilters OnderhoudVerlichting Vervanging VAN DE LampenPage Page AGA Rangemaster Group PLC