Installation Instructions

CONNECTING TO GAS SUPPLY

The cooker is designed to match the depth of standard 600mm worktops. An adaptor backplate should, therefore, be fitted within the shaded area shown to allow the cooker to be pushed fully to the wall.

220mm

70mm

GAS BACKPLATE

POSITION

40mm

635mm

30mm

450mm

Connection to the cooker should be made with an approved appliance flexible connection to BS 669. A length of 0.9 to 1.25m is recommended. The length of hose chosen should be such that when the cooker is in situ, the hose does not touch the floor.

The temperature rise of areas at the rear of the cooker that are likely to come in contact with the flexible hose do not exceed 70˚C.

32

Image 32
Contents Free Standing Gas Cooker Contents Introduction Safety Information AlwaysNever Guidance on Automatic Cooking Oven Timer Operation KD643G onlyAutomatic Cooking Know your Timer KD643G only ClockfaceSetting the Time of DAY Auto Cooking Programmes Page Other Notes on Timer Operation Hotplate To USE the HotplateSafety Requirements for Deep FAT Frying HOW to Deal with a FAT FireRelighting the Burner GrillTo USE the Grill Grill Main Oven Main Oven Cooking Chart Meat and PoultryYeast Mixtures ‘Slow Cook’ Setting Using the ‘SLOW COOK’ Setting for Slow CookingTo USE the TOP Oven Guidance on Using the TOP OvenTop Oven KD643G and KD641G only Top Oven Cooking Chart KD643G and KD641G only Gas Shelf Food Mark Oven Shelf Supports Care and CleaningMain Oven Heat Clean Linings Cooker Finish Cleaning Method Replacement of Oven Light BulbSide Opening Doors Drop Down DoorsProblem Check Something Wrong with your Cooker?Recommended setting slightly to suit your taste Installation Instructions GAS Safety Installation & USE RegulationsLocation Provision for VentilationNatural GAS Technical Data DimensionsGeneral Space for Fixing Cooker HoodsStability Bracket Unpacking the CookerLevelling Connecting to GAS Supply Installation Instructions Electrical Connection Connect to a 230-240V A.C. Supply onlyInstallation and Operational Checks Contact the Service Office UK 08709 066 If It Still Won’t WorkKey Contacts