hussman SCSS-SL manual EKC 201 Controllers, Quick guide

Page 10

IGSSB-SCSS / SCSS-SL-0108

EKC 201 CONTROLLERS

EKC 201

= 0

+55°C

troom

tsystem = –60

+50°C

12 V a.c./230 V a.c.

2.5 VA

IP 54

Fig. 1

Quick guide

Identification

(See figs 1 and 2).

1.Light emitting diode

= refrigeration

= defrost

= fan running

2.Minus sign

3.Display

(Flashes when setting value for room temp. is displayed).

4.Keys for programming and setting (see programming instructions).

Programming and setting

see programming instructions, parameter code, and settings.

Press upper key for 2 s.

Press lower key for 2 s.

Press both keys at the same time.

What

Initial

 

Operating the two pushbuttons

 

Resulting

controller

 

 

Display

 

controller

to do

 

 

 

 

 

 

readout

 

 

Read

Normal

 

Set

 

Room

Normal

or

operation

 

value

temp.

operation

change

 

 

 

 

 

 

room

 

Room

 

Change

Room

Room

temp.

Room

temp.

 

temp.

 

 

 

 

 

 

Read

Normal

 

Code

Set

 

Normal

operation

 

value

 

operation

or change

 

 

 

(or alarm)

 

 

 

 

(or alarm)

parameter

 

 

 

 

 

Room

 

 

Room

 

codes

Unknown

Change

Change

 

temp.

temp.

Known

and

 

 

codes

 

 

 

 

codes

 

 

 

 

 

 

 

 

 

 

 

All

Re-establish

Unknown

Room

 

Power

Room

parameter

all factory

Power off

settings

settings

temp.

on

temp.

 

 

= factory

 

 

 

 

 

 

Read

Normal

Room

 

 

Room

Normal

defrost

 

Defrost sensor temp.

sensor

operation

temp.

 

 

temp.

operation

 

 

 

 

 

or alarm

 

 

 

 

 

Manually

 

 

 

Defrost operation

 

 

 

 

 

 

 

 

start of

Normal

Room

 

 

Room

Normal

a defrost

operation

temp.

 

 

temp.

operation

 

 

 

 

Room temp.

 

 

Manually

 

 

 

 

 

 

stop of

Defrost

Room

 

Room temp.

Room

Normal

a defrost

operation

temp.

 

temp.

operation

 

 

Reset

Alarm

 

 

 

 

Alarm

Room

 

Alarm code/

Room

relay

alarm

relay

 

temp.

 

Fault code

temp.

not

relay

 

 

 

 

 

 

 

 

Read codes

Alarm relay

Room

 

Alarm code/

Room

Alarm

cause of

not

 

temp.

 

Fault code

temp.

 

alarm mode

activated

 

 

 

 

 

 

 

 

 

 

10

 

Image 10
Contents Service Bakery REVModel Descriptions ApplicationShortages Hussmann Chino Product ControlSCSS-SL Leveling Do not USE PermagumWaste Outlet and P-TRAP Installing Condensate DrainJoint Trim Corner WedgesLinesthrough Merchandisersthatare Stat Location Condensing Unit Installation RequirementsPiping Ashrae Color Code Wiring Color CodeRear CLOSE-OFF Panel EKC 201 Controllers Quick guideController application setting parameters Eration Case CleaningStocking Important StepsNON-GLARE Glass Evaporator pan must be monitored forPlexiglass & Acrylic Care Before calling for service, check the following Tips & TroubleshootingReplacing Fluorescent Lamps Electrical Schematics Controls lines W8100002mnl Controls lines Appendix B. Application Recommendations Refrigerated Appendix A. Temperature Guidelines RefrigeratedType Typical Entering Refrigerator AIR Temperature Appendix C. Field Recommendations RefrigeratedAppendix D. Recommendations to User Refrigerated Appendices, Cont’dAppendices, Cont’d IGSSB-SCSS / SCSS-SL-0108 Limited Warranty Model Serial Number