hussman SCSS-SL manual Wiring Color Code, Ashrae Color Code, Rear CLOSE-OFF Panel

Page 9

Rev. 0108

WIRING COLOR CODE

G R E E N

G RO U N D

P U R P L E

A N T I - S W E AT

O R A N G E

L I G H T S

Y E L L OW

R E C E P TA C L E

RED / BLACK

T- STAT /SOLENOID230V

BLACK / WHITE

T- STAT / SOLENOID 115V

BROWN

FAN MOTORS

 

 

CASE MUST BE GROUNDED

Electrical

WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes stamped on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration con trol panel to the merchandisers is required for refrigera- tion thermostats. Most component amperes are listed in the "Case Specs" section, but always check the serial plate.

ASHRAE COLOR CODE

NOTE: All other manufacturers; no known sensor codes

NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length fluores- cent lamps located within the case at the top.

The switch controlling the lights, the plug provided for digital scale, and the thermometer are located at the rear of the case mullion.

ELECTRICAL SERVICE RECEPTACLES (WHEN APPLICABLE)

The receptacle that is provided on the exterior back of these models is intended for computerized scales with a fifteen amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedicated circuit.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heat-

ers, Thermostats, and Lights.

FIELD WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for re- frigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs the length of the rear of the case.

Case Control Systems

SENSOR

COLORS

 

 

 

 

 

Manufacturer ® >

 

EIL

CPC

 

 

 

 

Location

 

 

 

 

 

 

 

Coil Inlet

Color

Blue

Blue

 

 

 

 

 

Part#

225-01-1755225-01-3255

 

 

 

 

Coil Outlet

Color

Red

Red

 

 

 

 

 

Part#

225-01-1757225-01-3123

 

 

 

 

Discharge Air

Color

Green

Green

 

 

 

 

 

Part#

225-01-1756225-01-3260

 

 

 

 

Return Air

Color

Purple

Green

 

 

 

 

 

Part#

225-01-1758225-01-3260

 

 

 

 

Defrost Term.

Color

White

Orange

 

 

 

 

 

Part#

225-01-0650225-01-3254

 

 

 

 

Liquid Line

Color

White

Blue

 

 

 

 

 

Part#

225-01-0650225-01-3255

 

 

 

 

REAR CLOSE-OFF PANEL

To perform electrical and refrigeration work, remove the rear closure panel by loosening the sheet metal screws. Replace when work is complete.

ELECTRICAL

Connections - All wiring must be in compliance with NEC and local codes. All electrical connections for the nonrefrigerated model are to be made in the electrical panel. Electrical connections for refrigerated models are made in the electrical box on the back of the case behind the rear close-off panel.

FieldWiring - Field wiring must be sized for components amperes stamped on the serial plate.Actual ampere draw may be less than specified.Always check the serial plate. Post Construction Clean-up-After the first two weeks of a major store remodel or new store operation, the grill should be removed and the condensing unit and condenser face cleaned due to the accumulated dirt and debris generated during construction.

9

Image 9
Contents REV Service BakeryApplication Model DescriptionsHussmann Chino Product Control ShortagesSCSS-SL Do not USE Permagum LevelingJoint Trim Installing Condensate DrainWaste Outlet and P-TRAP Corner WedgesLinesthrough Merchandisersthatare Condensing Unit Installation Requirements Stat LocationPiping Wiring Color Code Ashrae Color CodeRear CLOSE-OFF Panel Quick guide EKC 201 ControllersController application setting parameters Stocking Case CleaningEration Important StepsEvaporator pan must be monitored for NON-GLARE GlassPlexiglass & Acrylic Care Tips & Troubleshooting Before calling for service, check the followingReplacing Fluorescent Lamps Electrical Schematics Controls lines W8100002mnl Controls lines Type Typical Entering Refrigerator AIR Temperature Appendix A. Temperature Guidelines RefrigeratedAppendix B. Application Recommendations Refrigerated Appendix C. Field Recommendations RefrigeratedAppendices, Cont’d Appendix D. Recommendations to User RefrigeratedAppendices, Cont’d IGSSB-SCSS / SCSS-SL-0108 Limited Warranty Model Serial Number