Hill Phoenix ONRBH, ORBH manual Model Orbh, Coil

Page 9

41 7/16 in [105.2 cm]

 

 

 

Amp plate &

 

 

 

Serial Plate

 

 

 

location

 

 

68 in

 

 

 

[172.7 cm]

 

 

 

(Frame Height)

 

85 1/16 in

63 in

 

 

[160.1 cm]

 

 

[216.0 cm]

66 3/8 in

 

 

 

 

 

[168.6 cm]

 

87 1/16 in

 

(Door Height)

 

 

 

 

[221.1 cm]

 

 

 

 

 

 

1/2 BUMPER OPTION

 

30 7/8 in [78.4 cm]

 

 

 

COIL

16 1/16 in

7 1/2 in

 

PLENUM

[19.1 cm]

 

 

[40.9 cm]

 

5 1/8 in

6 13/16 in [17.2 cm]*

8 1/2 in

 

[21.6 cm]

 

 

 

[13.1 cm]

31 9/16 in [80.2 cm]

 

 

 

 

 

 

 

39 1/4 in [99.7 cm]

 

 

 

42 11/16 in [108.4 cm]

 

 

 

 

 

PIPING-TO-TOP

 

 

 

(OPTIONAL)

MODEL

ORBH

 

 

WIRING-TO-TOP

 

 

REAR REFRIGERATION

 

 

 

 

(13 15/16" off of floor)

8 in [20.3 cm]

 

(OPTIONAL)

12 3/4 in [32.4 cm]

 

3 3/8 in [8.6 cm]

 

 

 

 

 

10 in

 

 

 

 

 

[25.4 cm]

 

 

 

4 in [10.2 cm]

28 5/8 in

 

 

 

35 1/8 in

 

 

 

 

[72.7 cm]

 

 

 

[89.2 cm]

 

31 9/16 in

 

 

 

 

 

 

**

 

33 9/16 in

[80.2 cm]

 

 

 

 

 

 

 

 

 

 

 

 

[85.3 cm]

34 11/16 in

 

 

 

 

 

[88.1 cm]

 

ELECTRICAL

 

 

39 1/4 in

 

 

 

 

 

42 11/16 in

 

 

 

 

[99.7 cm]

 

 

 

 

 

[108.4 cm]

 

 

 

 

 

 

 

 

 

 

REFRIGERATION

JUNCTION BOX

 

 

 

 

1 1/2 in

(STANDARD)

 

 

 

 

[3.8 cm]

 

 

C

 

 

{END}

16 1/16 in [40.8 cm]

 

 

 

 

 

L

1 1/2" PVC DRAIN

8 11/16 in [22.1 cm]

 

 

18 9/16 in [47.1 cm]

 

CONNECTION

 

 

 

FRONT OF CASE

 

 

 

 

60 in [152.4 cm] {2 Door}

 

 

 

 

90 in [228.6 cm] {3 Door}

 

 

 

 

120 in [304.8 cm] {4 Door}

 

 

 

 

150 in [381.0 cm] {5 Door}

 

 

 

NOTES:

180 in [457.2 cm] {6 Door}

 

 

 

96 in [243.8 cm] {8' case}

 

 

 

 

 

 

 

 

144 in [365.8 cm] {12' case}

 

 

 

* STUB-UP AREA

 

 

 

 

** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

zENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT

zWIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT

zA 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL

zSUCTION LINE (ALL LENGTHS) 1/2"

zLIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"

zAVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20", 22" & 23 1/2"

SOLID SHELVES 18", 20", 22", 24" & 27"

(TOP SHELF MUST BE 24" OR SHORTER WHEN USING 27" SHELVES. RECOMMENDED CONFIGURATION IS 1 - 24" SHELF AND 4 - 27" SHELVES BELOW TOP SHELF)

5

Image 9
Contents Handbook Page Hill Phoenix Page Table of Contents Page General Information Model ORB General InformationCoil Model OrbhPlenum Coil Model OnrbPlenum Coil Model OnrbhNarrow Door Case Basehorse Location for Model ONRB, Onrbh ORB & OrbhCases Move on For Easier InstallationLine UP Remove Outriggers Trim OUT Color Refrigeration Piping Plumbing HOW to Remove Kickplate Lift UP from J Rail and Pull OUTElectrical Hookup Anthony Frames Ballast Locations Door Models Wiring DIAGRAMS- ORB, Orbh Onrb & Onrbh Door 12’ ORB, ORBH, Onrb & Onrbh Wiring DIAGRAMS-ORB & Orbh Wiring DIAGRAMS- GFI Case Operation High Glass Door Reach-in Beverage Merchandiser Narrow Glass Door Reach-in Beverage Merchandiser High Narrow Glass Door Reach-in Beverage Merchandiser Defrost and Temp Control Return AIR GRILL...4 DischargeUSE and Maintenance Door FansParts Ordering Model ORB, ORBH, Onrb & Onrbh Procedure Appendix a Page Warranty Maintenance & Case Care