DESCRIPTION OF CASES: The refrigerated display cases described in this handbook are part of the Hill PHOENIX, Origin2 design series. Specifically covered in this manual are

models ORB reach-in beverage, ORBH high reach-in beverage, ONRB narrow reach-in bev- erage, & ONRBH high narrow reach-in beverage.

STORE CONDITIONS: Hill PHOENIX cases are designed to operate in an air conditioned store with a system that can maintain 75OF (24OC) store temperature and 55 percent (maxi- mum) relative humidity (CRMA conditions). Case operation will be adversely affected by exposure to excessively high ambient temperatures and/or humidity.

REFRIGERATION SYSTEM OPERATION: Air cooled condensing units require ventilation for efficient performance of condensers. Machine room temperatures must be a minimum of 65OF in winter and a maximum of 95OF in summer. Minimum condensing temperatures should be no less than 70OF.

RECEIVING CASES: Examine fixtures carefully for shipping damage and shortages. For information on shortages contact the Service Parts Department at 1-800-283-1109.

APPARENT DAMAGE: A claim for obvious damage must be noted on the freight bill or express receipt and signed by the carriers agent, otherwise the carrier may refuse the claim.

CONCEALED DAMAGE: If damage is not apparent until after the equipment is unpacked, retain all packing materials and submit a written request to the carrier for inspection within 15 days of receipt of equipment.

LOST ITEMS: This equipment has been carefully inspected to insure the highest level of quality. Any claim for lost items must be made to Hill PHOENIX within 48 hours of receipt of equipment.

TECHNICAL SUPPORT: If any technical questions arise regarding a refrigerated display case contact our Customer Service Department in Richmond at 1-804-526-4455. For any questions regarding our refrigeration systems or electrical distribution centers contact our Customer Service Department in Conyers at 1-770-285-3200.

CONTACTING FACTORY: Should you need to contact Hill PHOENIX regarding a specific fixture, be sure to know the case model number and serial number. This information is on the serial plate located on the top flue panel of the case (see next page for details). Ask for a Service Parts Representative at 1-804-526-4455.

3

Image 7
Contents Handbook Page Hill Phoenix Page Table of Contents Page General Information Model ORB General InformationCoil Model OrbhPlenum Coil Model OnrbPlenum Coil Model OnrbhNarrow Door Case Basehorse Location for Model ONRB, Onrbh ORB & OrbhCases Move on For Easier InstallationLine UP Remove Outriggers Trim OUT Color Refrigeration Piping Plumbing HOW to Remove Kickplate Lift UP from J Rail and Pull OUTElectrical Hookup Anthony Frames Ballast Locations Door Models Wiring DIAGRAMS- ORB, Orbh Onrb & Onrbh Door 12’ ORB, ORBH, Onrb & Onrbh Wiring DIAGRAMS-ORB & Orbh Wiring DIAGRAMS- GFI Case Operation High Glass Door Reach-in Beverage Merchandiser Narrow Glass Door Reach-in Beverage Merchandiser High Narrow Glass Door Reach-in Beverage Merchandiser Defrost and Temp Control Return AIR GRILL...4 DischargeUSE and Maintenance Door FansParts Ordering Model ORB, ORBH, Onrb & Onrbh Procedure Appendix a Page Warranty Maintenance & Case Care