maintenance (Mixer)

GREASE FITTING

AND CAP

Figure 26. Grease Fittings (Countershaft)

Wheel Bearings

1.After every 3 months of operation, remove the hub dust cap and inspect the wheel bearings (Figure 27). Once a year, or when required, disassemble the wheel hubs remove the old grease and repack the bearings forcing grease between rollers, cone and cage with a good grade of high speed wheel bearing grease (never use grease heavier than 265 A.S.T.M. penetration (“No. 2.”).

BEARING

Main Gear and Drive Pinion Alignment

1.Disconnect the spark plug wire (gasoline engines). If mixer is equipped with an electric motor remove power cord from AC power receptacle. In addition make sure the clutch engagement lever is disengaged to relieve V-belt tension.

2.The countershaft and drive pinion are mounted on a slotted base.To align drive pinion with main gear, loosen the pillow block mounting bolts and move them until the necessary alignment has been made. Remember gears must be paralleled aligned not skewed.

3.Using your hand, slightly move (rock) the drive pulley back and forth to determine the amount of backlash. Insert feeler gauge between gears to determine backlash distance. Backlash should range between 0.007- 0.012 inches (Figure 28).

MAIN GEAR

CONE

OIL

SEAL

WHEEL

HUB

MAIN GEAR

GEAR TEETH

 

 

 

 

 

DRIVE

 

PINION GEAR

PINION

 

 

BEARING

CUP

Figure 27. Wheel Hub and Bearings

2.Fill the wheel hub (Figure 27) with grease to the inside diameter of the outer races and also fill the hub grease cap. Reassemble the hub and mount the wheel. Then tighten the adjusting nut, at the same time turn the wheel in both directions, until there is a slight bind to be sure all the bearing surfaces are in contact.

Then back-off the adjusting nut 1/6 to 1/4 turn or to the nearest locking hole or sufficiently to allow the wheel to rotate freely within limits of .001” to .010” end play. Lock the nut at this position. Install the cotter pin and dust cap, and tighten all hardware.

0.007 - 0.012 INCHES

(MAX. BACKLASH)

Figure 28. Drive Pinion and Main Gear

(Backlash)

WM70SH5C/wm70sh8c Mixer • operation and parts manual — rev. #0 (06/07/11) — page 27

Image 27
Contents WM70SH5C Proposition 65 Warning Silicosis Warning Silicosis/Respiratory WarningsWM70SH5C/WM70SH8C Table of ContentsChoose from three easy options Burn hazards Safety informationSaFeTY MeSSageS Explosive fuel hazardsGeneral SaFeTY Mixer SaFeTY Engine SaFeTY gaSoline ModelS onlYBefore servicing equipment Power Cord/Cable Safety Fuel SaFeTY gaSoline ModelS onlYGeneraTor SaFeTY EleCTriC MoTor SaFeTY eleCTriC ModelS onlYToWing SaFeTY EnvironMenTal SaFeTY„ alWaYS shutdown engine before transporting Tow Bar to Mixer Connection Safety chain connectionLbs kg SpecificationsDimensions DimensionsApplication Power PlantsEngine Maintenance Hardware General informationComponents Inspection Before StartingEngine Oil Check Blade Check Controls Start/Stop SwitchesFuel Check Belt CheckInitial Servicing Basic engineAdjust paddles as shown in Figure Paddle blade adjustmentStart-up Turn the engine switch to the on positionBelt Slip Lever Start/Stop Position Operation Mixing/DumpingStopping the Mixer Page First Every Maintenance engineEngine air cleaner Install drain bolt with sealing washer and tighten securelyEngine oil Drum Bearing Bracket Lubrication Maintenance MixerBall Socket and Clamp Face Maintenance Drum Head SealsMain Gear and Drive Pinion Alignment Wheel BearingsTires Wear/Inflation InspectTooth Contact between Main Gear and Drive PinionGear Lubrication Tires/Wheels/Lug NutsLug Nut Torque Requirements Start all wheel lug nuts by handNever use an pneumatic air gun to tighten wheel lug nuts Suspension Mixer CleaningMixer Storage Troubleshooting engine TroubleshootingAir cleaner dirty? Clean or replace air cleaner Defective or worn drum support Adjust if necessaryDrum difficult to discharge tilt Blades adjusted too tight Replace sealsWiring diagram Explanation of Code in Remarks Column Rope, recoil starter GX160 Element, air cleaner GX160Suggested Spare Parts BeltInstructions DE Sécurité Nameplate and decalsEM948630 Decal, push to stop English Decal, safety instructions English 515275Decal, safety instructions french DECAL, handle kick back, safety grate Crush hazardFrame assy 507444 514842491692 530023Engine END Paddle shaft assyEM202898 514752492584 NUT, Lock 1/2 EM202896 492399 B0LT, 1/2 X EM200292Steel tub assy 491008 530028C3249 20561-001Axle assy 8164 34698115 3005Engine assy 513868 EM969013 NUT 3/8 NC G5 506488EM905016 492378 Bolt 3/8 NC X 1-3/4 G5 490957Cabinet assy 491010 520620EM505186 503723FreigHT poliCY Terms and conditions of sale partsPage HERE’S HOW to GET Help

WM70SH8C, WM70SH5C specifications

The Multiquip WM70SH5C and WM70SH8C are cutting-edge water pump models designed for construction and industrial applications. These robust machines are specifically engineered to handle a variety of heavy-duty pumping tasks, making them an essential asset for contractors and industrial operators alike.

The WM70SH5C model is powered by a reliable 5.5 HP Honda engine, while the WM70SH8C variant features an 8 HP Honda engine, providing additional power for demanding applications. Both models are equipped with a high-performance centrifugal pump, ensuring efficient water transfer and quick operation. They are capable of moving large volumes of water, making them suitable for dewatering, irrigation, and other water management tasks.

One of the standout features of the WM70SH series is their impressive maximum flow rate. The pumps can deliver up to 2,000 gallons per minute, significantly reducing the time required for water removal in flooded areas or construction sites. This efficiency is crucial in maintaining project timelines and ensuring safety in work environments.

Durability is another key characteristic of these models. The WM70SH5C and WM70SH8C are built with heavy-duty materials, including a cast iron pump housing and aluminum alloy components, which resist corrosion and ensure a long operational lifespan. Additionally, their rugged construction allows them to withstand harsh working conditions, making them reliable even in the toughest environments.

Ease of use and maintenance is also a priority in the design of these pumps. The WM70SH series features an easy-access maintenance panel that simplifies routine checks and service procedures. The equipped oil alert system helps prevent engine damage by shutting down the engine if the oil level is too low, providing peace of mind for operators.

Both models are designed for portability, with integrated handles and a lightweight frame that facilitate easy transportation. This mobility makes the WM70SH series ideal for contractors who need to move equipment frequently from one job site to another.

In summary, the Multiquip WM70SH5C and WM70SH8C water pumps stand out in the market for their powerful performance, robust construction, and ease of use. They are designed to deliver efficiency, reliability, and durability, making them an excellent choice for any water pumping requirements in construction and industrial applications. With features catering to the demands of heavy-duty tasks, these pumps enhance productivity while ensuring operational safety.