Multiquip WM70SH8C Fuel SaFeTY gaSoline ModelS onlY, GeneraTor SaFeTY, Power Cord/Cable Safety

Page 9

safety information

Fuel SaFeTY (gaSoline ModelS onlY)

danger

„do noT start the engine near spilled fuel or combustible fl uids. Fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

„alWaYS refuel in a well-ventilated area, away from sparks and open fl ames.

„alWaYS use extreme caution when working with flammable liquids.

„do noT fi ll the fuel tank while the engine is running or hot.

„do noT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

„never use fuel as a cleaning agent.

„do noT smoke around or near the equipment. Fire or explosion could result from fuel vapors or if fuel is spilled on a hot engine.

generaTor SaFeTY

If using a generator to power mixer, refer to applicable generator manual safety information section.

eleCTriC MoTor SaFeTY (eleCTriC ModelS onlY)

NOTICE

„Operate electric motor only at the specifi ed voltage indicated on the nameplate.

„do noT spray water onto electric motor.

„alWaYS disconnect AC power plug from power source before moving mixer.

„ alWaYS make sure the ON/OFF switch on the electric motor is in the OFF position when not in use and before inserting the mixer’s power plug into an AC receptacle.

power Cord/Cable Safety

danger

„never let power cords or cables lay in water.

„never use damaged or worn cables or cords when connecting equipment to generator. Inspect for cuts in the insulation.

„ never grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

„Make sure power cables are securely connected. Incorrect connections may cause electrical shock and damage to the mixer.

CauTion

„Ensure that cables and cords will not be tripped over or trapped underneath the mixer.

NOTICE

„alWaYS make certain that proper power or extension cord has been selected for the job.

TranSporTing SaFeTY

CauTion

„never allow any person or animal to stand underneath the equipment while lifting.

NOTICE

„alWaYS make sure forklift forks are inserted into pockets (if applicable) as far as possible when lifting the mixer.

„alWaYS shutdown engine before transporting.

„never lift the equipment while the engine is running.

„Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling.

„do noT lift machine to unnecessary heights.

„alWaYS tie down equipment during transport by securing the equipment with rope.

„never tip the engine to extreme angles during lifting as it may cause oil to gravitate into the cylinder head, making the engine start diffi cult.

WM70SH5C/wm70sh8c Mixer • operation and parts manual — rev. #0 (06/07/11) — page 9

Image 9
Contents WM70SH5C Proposition 65 Warning Silicosis Warning Silicosis/Respiratory WarningsWM70SH5C/WM70SH8C Table of ContentsChoose from three easy options SaFeTY MeSSageS Safety informationExplosive fuel hazards Burn hazardsGeneral SaFeTY Mixer SaFeTY Engine SaFeTY gaSoline ModelS onlYBefore servicing equipment GeneraTor SaFeTY Fuel SaFeTY gaSoline ModelS onlYEleCTriC MoTor SaFeTY eleCTriC ModelS onlY Power Cord/Cable SafetyToWing SaFeTY EnvironMenTal SaFeTY„ alWaYS shutdown engine before transporting Tow Bar to Mixer Connection Safety chain connectionLbs kg SpecificationsDimensions DimensionsEngine Maintenance Hardware Power PlantsGeneral information ApplicationComponents Inspection Before StartingEngine Oil Check Fuel Check Controls Start/Stop SwitchesBelt Check Blade CheckInitial Servicing Basic engineAdjust paddles as shown in Figure Paddle blade adjustmentStart-up Turn the engine switch to the on positionBelt Slip Lever Start/Stop Position Operation Mixing/DumpingStopping the Mixer Page First Every Maintenance engineEngine air cleaner Install drain bolt with sealing washer and tighten securelyEngine oil Ball Socket and Clamp Face Maintenance Maintenance MixerDrum Head Seals Drum Bearing Bracket LubricationMain Gear and Drive Pinion Alignment Wheel BearingsGear Lubrication InspectTooth Contact between Main Gear and Drive PinionTires/Wheels/Lug Nuts Tires Wear/InflationLug Nut Torque Requirements Start all wheel lug nuts by handNever use an pneumatic air gun to tighten wheel lug nuts Suspension Mixer CleaningMixer Storage Troubleshooting engine TroubleshootingAir cleaner dirty? Clean or replace air cleaner Drum difficult to discharge tilt Blades adjusted too tight Adjust if necessaryReplace seals Defective or worn drum supportWiring diagram Explanation of Code in Remarks Column Suggested Spare Parts Element, air cleaner GX160Belt Rope, recoil starter GX160Instructions DE Sécurité Nameplate and decalsDecal, safety instructions french Decal, safety instructions English 515275DECAL, handle kick back, safety grate Crush hazard EM948630 Decal, push to stop EnglishFrame assy 491692 514842530023 507444Engine END Paddle shaft assy492584 NUT, Lock 1/2 EM202896 514752492399 B0LT, 1/2 X EM200292 EM202898Steel tub assy 3249 530028C20561-001 491008Axle assy 8115 34693005 8164Engine assy EM905016 EM969013 NUT 3/8 NC G5 506488492378 Bolt 3/8 NC X 1-3/4 G5 490957 513868Cabinet assy EM505186 520620503723 491010FreigHT poliCY Terms and conditions of sale partsPage HERE’S HOW to GET Help

WM70SH8C, WM70SH5C specifications

The Multiquip WM70SH5C and WM70SH8C are cutting-edge water pump models designed for construction and industrial applications. These robust machines are specifically engineered to handle a variety of heavy-duty pumping tasks, making them an essential asset for contractors and industrial operators alike.

The WM70SH5C model is powered by a reliable 5.5 HP Honda engine, while the WM70SH8C variant features an 8 HP Honda engine, providing additional power for demanding applications. Both models are equipped with a high-performance centrifugal pump, ensuring efficient water transfer and quick operation. They are capable of moving large volumes of water, making them suitable for dewatering, irrigation, and other water management tasks.

One of the standout features of the WM70SH series is their impressive maximum flow rate. The pumps can deliver up to 2,000 gallons per minute, significantly reducing the time required for water removal in flooded areas or construction sites. This efficiency is crucial in maintaining project timelines and ensuring safety in work environments.

Durability is another key characteristic of these models. The WM70SH5C and WM70SH8C are built with heavy-duty materials, including a cast iron pump housing and aluminum alloy components, which resist corrosion and ensure a long operational lifespan. Additionally, their rugged construction allows them to withstand harsh working conditions, making them reliable even in the toughest environments.

Ease of use and maintenance is also a priority in the design of these pumps. The WM70SH series features an easy-access maintenance panel that simplifies routine checks and service procedures. The equipped oil alert system helps prevent engine damage by shutting down the engine if the oil level is too low, providing peace of mind for operators.

Both models are designed for portability, with integrated handles and a lightweight frame that facilitate easy transportation. This mobility makes the WM70SH series ideal for contractors who need to move equipment frequently from one job site to another.

In summary, the Multiquip WM70SH5C and WM70SH8C water pumps stand out in the market for their powerful performance, robust construction, and ease of use. They are designed to deliver efficiency, reliability, and durability, making them an excellent choice for any water pumping requirements in construction and industrial applications. With features catering to the demands of heavy-duty tasks, these pumps enhance productivity while ensuring operational safety.