INSTALLING YOUR REFRIGERATOR

Select Location

The proper location will ensure peak performance of your appliance. We recommend a location where the unit will be out of direct sunlight and away from heat sources. To assure your product performs to specifications the recom- mended installation location temperature range is from 65 to 90°F (18 to 32°C).

Outdoor Installation

Only the 3OARM & 6OARM models are suitable for out- door installations. A ground fault circuit interrupter electri- cal receptacle is to be used to supply electrical power to the refrigerator for outdoor applications. Contact an electri- cian if you need to install one to supply electrical power to your outdoor refrigerator. Do not install in an environment where the unit will be exposed to direct sun exposure as this may result in unsatisfactory performance.

Cabinet Clearance

Ventilation is required from the bottom front section of the unit. Keep this area open and clear of any obstructions. Adjacent cabinets and counter top can be installed around the unit as long as the grille and door access remain unob- structed.

Front Grille

Do not obstruct the front grille. The openings within the front grille provides air to flow into and exit from the refrig- erator condenser. For this reason it is important this area to not be obstructed and be kept clean. Marvel does not rec- ommend the use of custom made grilles as air flow may be restricted because of inadequate openings. (See Figure 1).

Front Grille, keep this area open.

Figure 1

Leveling Legs

Leveling Legs

Adjustable legs at the front and rear corners of the unit should be set so the unit is firmly positioned on the floor and level from side to side and front to back. Turn leveling legs clockwise to raise unit, counterclockwise to lower it. (See Figure 1).

Do not splash or spray water from a hose on the re- frigerator! Doing so may cause an electrical shock, which may result in severe injury or death.

This unit should not, under any circumstances, be ungrounded.

Grounding Method

This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be plugged into a mating grounding type receptacle in accor- dance with the National Electrical Code and applicable lo- cal codes and ordinances (see Figure 2). If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed.

Electrical Connection

115 volts, 3.3 amps running max. 15 amp dedicated circuit required. 3 prong grounded receptacle required.

Do not use an extension cord with this appliance.

Figure 2

3

Image 4
Contents Marvel 30ARM 61ARM 3OARM 6OARM 6ADAMTable of Contents Unpacking Your Refrigerator Installing Your Refrigerator Using Your MicroSentry Refrigerator Control Using Your MicroSentry Refrigerator Control Dimensions for Models 30ARM & 3OARM Dimensions for Models 30ARM with Overlay Door Dimensions for Models 61ARM & 6OARM Dimensions for Model 61ARM with Overlay Door Dimensions for Model 6ADAM Recommended Rough In Opening Dimensions, Model 6ADAMDimensions for Model 6ADAM with Overlay Door Full Overlay Panel Installation Instructions 6ADAMMaterial Type #8 Wood Screw Right hand Hinges shown Care and Cleaning Troubleshooting Your Refrigerator Household Product Warranty Appendix A, Additional MicroSentry Features EN Rev G 11/10/09