(2) Timing in self-check
Trouble of Defrost heater | : | |
| (Make sure to confirm the display before unplugging the power cord | |
| because it is automatically reset once the power cord is pulled out.) | |
Trouble of Ice maker | : Press the | switch on the panel for 5 seconds. (Ice making test mode.) |
| The setting of ice making compartment blinks on LCD during the test operation. | |
Trouble of Fan motor | : Open the door and then closed it. | |
| When abnormality is found in fan motor, buzzer sound is heard every time the door | |
| is closed. |
|
Trouble of Inverter | : Check the error when compressor starts up or is operating. | |
Trouble of Thermistor | : |
(3) Error display and trouble locating
1. Display details
After conducting the
(Ex.) In case the errors of ice tray thermistor (e10), refrigerator thermistor (e13) and refrigerator fan motor (e31) are happening simultaneously;
TEMP
TEMP
e ➝ 10 ➝ 13 ➝ 31 ➝ e ➝ 10 ➝ 13 ➝ 31 ·····
✻For 2 minutes in
2. Check point and treatment | (Ex.) When ice maker gear |
| box is defective. |
Display
Testing
LCD |
Error code | Trouble | Detecting method |
| Check point | Treatment | Control | ||
(*3) |
| |||||||
|
|
|
|
|
|
|
| |
| (*1) |
| Ice maker is under testing |
|
| |||
|
|
|
|
|
|
|
| |
|
|
| (*5) | When the following communi- | 1. | Connector CN8K, CN7S on control board | Repair the | Keep the same operation as |
|
|
| Communication | cation errors occur |
| contact failure. | the one before the communi- | |
|
|
| error of | between control board and |
|
| cation error has occurred. | |
|
|
| operation P.C. board: |
|
| |||
|
|
| operation panel |
|
|
|
| |
e |
| 01 | •They transmit and receive |
|
|
|
| |
|
| data that has nothing to do |
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
| with settings. | 2. | Trouble of control board and operation | Replace |
|
|
|
|
| •They cannot transmit and |
| P.C. board |
|
|
|
|
|
| receive data each other |
|
|
|
|
|
|
|
| for about two seconds. |
|
|
|
|
|
|
| Communication | When abnormality is found in |
|
| Replace the | Compressor OFF. |
|
|
| error of inverter | the communication between |
|
| control |
|
e |
| 02 |
| refrigerator control circuit and |
|
| board. |
|
|
| inverter control circuit in con- |
|
|
| |||
|
|
|
|
|
| |||
|
|
|
| trol board. (When they do not |
|
|
|
|
|
|
|
| transmit and receive data for |
|
|
|
|
|
|
|
| 10 seconds.) |
|
|
|
|
|
|
| Trouble of | When the model of con- | 1. | Check the model name of control board | Replace | Keep operating the unit, and |
e |
| 03 | model judge- | trol board is different from |
|
|
| conduct error code indication |
|
|
| ment | the one of operation P.C. | 2. | Check the operation p.c. board. | Replace | only. |
|
|
|
| board. |
| |||
|
|
|
|
|
|
|
| |
|
|
| Trouble of ice | When there is a short or | 1. | Connector CN7S on control board, Ice gear | Repair the | When the compartment door |
|
|
| making tray | open circuit in the ice |
| box | contact failure. | has been closed for 3 hours |
e |
| 10 | thermistor | making tray thermistor. |
| connector |
| and when freezer compartment |
|
|
|
|
| 2. | Check the resistance of thermistor. | Replace | thermistor is |
|
|
|
|
| detecting operation starts. | |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Trouble of | When there is a short or | 1. | Connector CN7S on control board. | Repair the | After 10 minutes off, the |
e |
| 11 | freezer com- | open circuit in the freezer |
| relay connector | contact failure. | compressor repeats 30- |
|
|
| partment | compartment thermistor. |
|
|
| minute ON and |
|
|
| thermistor |
| 2. Check the resistance of thermistor. | Replace | OFF. | |
|
|
| Trouble of | When there is a short or | 1. | Connector CN7S on control board. | Repair the | The defrost heater won’t be |
e |
| 12 | defrost | open circuit in the defrost |
| relay connector | contact failure. | turned ON. |
| thermistor | thermistor. |
|
|
|
| ||
|
|
| 2. | Check the resistance of thermistor. | Replace |
| ||
|
|
|
|
|
| |||
|
|
| Trouble of | When there is a short or | 1. | Connector CN7S on control board, | Repair the | Synchronize the open/close |
e |
| 13 | refrigerator | open circuit in the refrig- |
| relay connector | contact failure. | status of R damper with that |
|
|
| thermistor | erator compartment ther- |
|
|
| of C damper. |
|
|
|
| mistor. | 2. | Check the resistance of thermistor. | Replace |
|
|
|
| Trouble of | When there is a short or | 1. | Connector CN7S, on control board, | Repair the | Synchronize the open/close |
e |
| 14 | chilled compart- | open circuit in the chilled |
| relay connector | contact failure. | status of C damper with that |
|
|
| ment thermistor | compartment thermistor. |
|
| Replace | of R damper. |
|
|
|
|
| 2. | Check the resistance of thermistor. |
| |
|
|
| Trouble of | When there is a short or | 1. Connector CN7S on control board, | Repair the | •When | |
|
|
| versa compart- | open circuit in the versa |
| relay connector | contact failure. | used as “freezer”: |
|
|
| ment thermis- | compartment thermistor. |
|
|
| is open when compressor is |
|
|
| tor |
|
|
|
| turned on, |
|
|
|
|
|
|
| closed when compressor is | |
|
|
|
|
|
|
|
| |
e |
| 15 |
|
| 2. Check the resistance of thermistor. | Replace | turned off. | |
|
|
| •When | |||||
|
|
|
|
|
|
|
| used other than “freezer”: S- |
|
|
|
|
|
|
|
| damper remains open for |
|
|
|
|
|
|
|
| the first 3 minutes and then |
|
|
|
|
|
|
|
| closed for the rest of time. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Versa(select) compartment. |
|
|
| Trouble of veg- | When there is a short or | 1. | Connector CN7S on control board, | Repair the | •When |
e |
| 16 | etable compart- | open circuit in the veg- |
| relay connector | contact failure. | |
|
|
| ment thermistor | etable compartment ther- |
|
|
| •When |
|
|
|
| mistor . | 2. | Check the resistance of thermistor. | Replace | |
|
|
|
|
|
|
|
|
|