Display
| LCD |
Error code | Trouble |
| Detecting method |
| Check point | Treatment | Control | |
| (*3) |
| ||||||
|
|
|
|
|
|
|
| |
|
| Trouble of ice | When there is a short or |
| 1. Connector CN7S on control board, | Repair the | •When ice making compart- | |
|
|
| ||||||
|
| making com- | open circuit in the ice |
| contact failure. | ment is used as “refrigera- | ||
|
| partment |
| making compartment |
|
|
| tor”, synchronize |
e | 17 | thermistor |
| thermistor. |
|
|
| with |
|
|
|
|
|
| 2. Check the resistance of thermistor. | Replace | •When ice making compart- |
|
|
|
|
|
| ment is used as “ice mak- | ||
|
|
|
|
|
|
|
| ing”, synchronize |
|
|
|
|
|
|
|
| with |
|
| Trouble of out- | When there is a short or |
|
| Replace the | Compressor is activated at | |
e | 18 | side air ther- | open circuit in the out- |
|
| operation | ||
|
| mistor |
| side air thermistor. |
|
| P.C. board. |
|
|
| Trouble of |
| When defrosting is not |
| 1. Connector CN2A on control board | Repair the | The defrost heater is |
|
| defrost heater | finished in 2 hours. |
| Defrost heater plug and receptacle, | contact failure. | stopped and if the next | |
|
| (*6) |
|
|
| relay connector |
| defrosting finishes in 2 |
e | 30 |
|
|
|
| Thermal fuse |
| hours, the error code will |
|
|
|
|
|
| 2. Check the resistance of defrost heater. | Replace | disappear . |
|
|
|
|
|
| 3. Check the continuity of thermal fuse. | Replace |
|
|
|
|
|
|
|
|
| |
|
| Trouble of refrig- | •When motor doesn’t |
| 1. Connector CN4D on control board, | Repair the | •3 minutes later, the refrigerator | |
|
| erator fan motor | rotate even though |
| Refrigerator fan motor | contact failure. | fan motor is reactivated to be | |
e | 31 | power is on. |
| checked. | ||||
|
| •When the waveform, |
|
|
| •Until the fan motor gets to oper- | ||
|
|
|
| which indicates the rota- |
|
| Replace | |
|
|
|
|
| 2. Check refrigerator fan motor operation. | ate correctly, the buzzer sounds | ||
|
|
|
| tion times of motor, can- |
| |||
|
|
|
| not be detected. |
|
|
| every time the door is closed. |
|
| Trouble of |
| •When motor doesn’t |
| 1. Connector CN4D on control board, | Repair the | •3 minutes later, the machine |
|
| machine cham- | rotate even though |
| contact failure. | chamber fan motor is reactivated | ||
e | 32 | power is on. |
| to be checked. | ||||
|
|
|
|
| ||||
ber fan motor | •When the waveform, |
|
|
| •Until the fan motor gets to oper- | |||
|
|
|
| which indicates the rota- |
|
|
| ate correctly, the buzzer sounds |
|
|
|
| tion times of motor, can- |
| 2. Check machine chamber fan motor operation. | Replace | |
|
|
|
| not be detected. |
| every time the door is closed. | ||
|
|
|
|
|
|
|
| |
|
| Trouble of ice | When the gear box operation |
| 1. Connector CN8K on control board, | Repair the | 100 minutes later, the gear box is | |
|
| maker gear box | is not finished in 30 seconds. |
| Ice gear box | contact failure. | reactivated to be checked again. | |
e | 33 |
|
|
|
| tor |
|
|
|
|
|
| 2. Ice gear box frozen point | Replace |
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
| 3. Check the trouble of the ice gear box with the | Replace |
|
|
|
|
|
|
| ice making test operation. |
|
|
|
| Clogging of |
| (T0: Defrost thermistor tem- | Check the compressor and the pipe. |
| When cooling operation returns to | |
|
| refrigerant |
| perature at power input, T1: |
|
|
| normal condition, the display of |
|
|
| Defrost thermistor tempera- |
|
|
| ||
e | 34 | pipe or trouble | ture when 15 minutes have |
|
|
| error code disappears. | |
passed from the power input) |
|
|
|
| ||||
|
| related to |
| •When the difference |
|
|
|
|
|
| compressor | between T0 and T1 is |
|
|
|
| |
|
|
|
| T0[T1. (*5) |
|
|
|
|
|
| Trouble of elec- | When defrost thermistor reads |
| Connector CN9D on control board | Repair the | Check the operation of electro- | |
e | 41 | tromagnetic |
|
| contact failure. | magnetic | ||
| after the compressor’s |
| ||||||
|
| startup.(*5) |
|
|
| then open the valve. | ||
|
|
|
|
|
|
|
| |
e |
| Trouble of invert- | •When there is any trouble in |
|
|
|
| |
50 | er circuit | (*6) | the circuit which detects cur- |
|
|
|
| |
|
|
|
| rent of compressor. |
|
|
|
|
|
|
|
|
|
|
|
| |
e | 51 | Trouble of bus- | •When the range of |
|
|
|
| |
bar voltage | (*6) | voltage is not approx. DC |
|
|
|
| ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
e | 52 | Trouble of inverter | •When the inverter driving |
|
|
| The compressor is suspend- | |
software reset | software malfunctions. |
| Refer to “Compressor does not operate” at page 21. |
| ed and reactivated 10 min- | |||
|
| function |
|
|
|
| ||
|
|
|
|
|
|
| utes later. | |
|
| Trouble of startup | •When there is no current at |
|
|
| ||
|
|
|
|
|
| |||
|
| compressor startup. |
|
|
|
| ||
|
| , synchronization | •When phase current exceeds |
|
|
|
| |
e | 53 | or overcurrent | 5.5A at compressor startup. |
|
|
|
| |
•When phase current exceeds |
|
|
|
| ||||
|
| detection |
| 3.3A during compressor oper- |
|
|
|
|
|
|
| (*6) | ation. |
|
|
|
|
|
|
| •When current of 5.3A or more |
|
|
|
| |
|
|
|
| runs into the |
|
|
|
|
|
|
|
| control board. |
|
|
|
|
|
| Trouble of power | When |
| 1. Different voltage of power supply outlet | Replace | Refrigerator compartment room | |
e | 54 | supply voltage | wave voltage) is DC 390V or |
|
| the control | light OFF | |
|
| Heaters. OFF | ||||||
|
| (*6) | above in power input. |
| 2. Trouble of relay in the circuit on the control board | board. | ||
|
|
|
|
|
|
|
| |
|
| Trouble of con- | EEPROM (IC11M) |
|
| Replace | When abnormality occurs in | |
|
| trol board | (*6) | accumulates data necessary |
|
| the control | power input, the compressor |
e | 55 | (EEPROM |
| for control. |
|
| board. | is suspended for 10 minutes. |
related trouble) | •When the data are not input |
|
| When abnormality occurs in | ||||
|
| accurately. |
|
|
| normal operation, the com- | ||
|
|
|
| •When microcomputer cannot |
|
|
| |
|
|
|
| read the data. |
|
|
| pressor keeps operating. |
|
| Defective wiring | The errors 50 to 53 keep |
|
|
| •Error display starts after it is | |
|
| continuity or |
| occurring over one and a half |
|
|
| regarded as e56. |
|
|
| hour. |
|
|
| •Error display continues until | |
|
| trouble of control |
|
|
| |||
|
| (the situation, which com- |
|
|
| defrosting starts or cooling oper | ||
e | 56 | board |
| pressor cannot be operated, |
| Refer to “Compressor does not operate” at page.22. |
| ation gets back to normal. (Error |
|
|
|
| continues.) |
|
|
| display doesn’t disappear by |
|
|
|
| Overcurrent detection error |
|
|
| unplugging and plugging the |
|
|
|
| occurred before the |
|
|
| power cord.*7) |
|
|
|
| compressor is activated. |
|
|
| •Try to restart compressor every 3 |
|
|
|
|
|
|
|
| minutes. |
|
|
|
|
|
|
|
|
|
*1 : The setting of ice making compartment will be displayed and blinks during or after ice making test operation.
*2 : This operation is called the recovery operation:
If the damper has not operated ever once during the compressor operation, make the damper operate when the compressor stops. *3 : When the resistance is ∞ ', the circuit is deemed
When the resistance is 0', the circuit is deemed
*4 : Once e01 is detected, other errors would be ignored and not displayed on the panel.
*5 : Characteristic value may change in order to improve the product.
*6 : The error codes e50 to e55 are not displayed even if those abnormalities occur at power input.
Therefore, be sure to perform ice making test operation in order to check if any abnormality indicated by these error codes occurs. (See page 14.)
*7 : If those errors still continue for 1minute after the restart, e56 will be displayed again.
16