Mitsubishi Electronics MR-G50J-SS-NZ manual Trouble Criterion of Main Parts MR-G50J-NZ

Page 26

6-6 TROUBLE CRITERION OF MAIN PARTS MR-G50J-NZ

Components/

 

 

Check Method and Criterion

 

 

 

 

Parts Mounted

Part Name

 

 

 

 

 

 

Position

 

 

 

 

 

 

 

 

 

 

 

Compressor

Black

 

Model

 

 

ETI100E13DAH

 

In the machine

 

 

 

 

 

chamber at the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated input

W

45/159 (1620/4800rpm)

 

rear side of the

 

 

 

 

frame.

 

 

 

Starting current

A

 

 

2.0

 

 

 

 

 

 

 

 

White

 

Running current

A

0.03/2.19 (1620/4800rpm)

 

 

Red

 

 

 

 

 

Abnormal

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

(faulty)

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance

 

Winding

 

 

Open (' )

 

 

with a tester.

 

 

9.3 '

 

 

 

(Black-White)

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

(White-Red)

(20:)

short circuit

 

 

 

 

 

(Red-Black)

 

 

 

(0' )

 

 

Motor

Model

 

 

 

 

MM3-71CCV

 

 

In the machine

protector

 

 

 

 

 

 

chamber at the

 

 

 

 

 

 

 

 

 

 

 

 

Connected Open

 

 

100 ±50 : or more

 

rear side of the

 

 

 

 

frame.

 

Energize it at 17.0A, 25: for 16 seconds at the longest.

 

point

 

 

 

 

Close

 

 

 

61±8: or less

 

 

 

 

 

 

 

 

 

Measure the resistance with a tester. (Ambient temperature : Room temperature)

 

 

Contact point

 

 

 

Normal

 

Abnormal (faulty)

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Less than 1'

 

Open circuit (∞ ' )

 

1

2

 

 

 

 

 

 

 

 

 

 

 

Refrigerator

 

Model

 

 

 

UDQM002B3

 

 

 

In the fan grille

fan motor

 

 

 

 

DC brushless

 

 

 

of the freezer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compartment.

 

 

Number of pole

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

{150 (Mixed flow fan)

 

 

Measure the resistance with a tester. (Ambient temperature : Room temperature)

 

 

 

 

 

 

 

Normal

 

 

Abnormal

 

 

 

 

 

 

 

 

 

 

(faulty)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Between 1 and 4 (GND and IC

Between 1 and 4

 

 

 

 

 

 

Power): About 12 k'

 

 

: open circuit (' )

 

 

 

 

 

 

Between 3 and 4 (Power and

 

Between 3 and 4

 

 

 

 

 

 

IC Power): '

 

 

:short circuit (0' )

 

 

 

 

 

 

 

4

IC Power

 

 

 

 

 

 

 

 

 

 

 

3

Power

 

 

 

 

 

 

 

 

 

 

 

2

FG

 

 

 

 

 

 

 

 

 

 

IC

1

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2 3 4 : Pin No.

 

 

 

 

 

 

 

 

 

Machine

 

Model

 

 

 

UDQM004B3

 

 

 

 

In the machine

chamber fan

 

 

 

 

DC brushless

 

 

 

 

chamber at the

 

 

 

 

 

 

 

 

 

motor

 

Number of pole

 

 

 

10

 

 

 

 

rear side of the

 

 

Diameter

 

 

 

{140 (Extra fan)

 

 

 

 

frame.

 

 

 

 

 

 

 

 

 

 

 

 

Operation method

During compressor operation

 

 

Measure the resistance with a tester. (Ambient temperature : Room temperature)

 

 

 

 

 

 

 

Normal

 

 

Abnormal (faulty)

 

 

 

4

IC Power

Between 1 and 4 (GND and IC

Between 1 and 4

 

 

 

3

Power

 

 

 

 

2

FG

 

Power): About 9 k'

 

 

: open circuit (

' )

 

 

 

1

GND

 

 

 

 

 

 

 

 

 

 

 

IC

 

 

 

 

 

 

 

 

 

 

1 2 3 4

: Pin No.

 

 

 

Between 3 and 4 (Power and

Between 3 and 4

 

 

 

 

 

IC Power): '

 

 

:short circuit (0' )

 

 

 

 

 

 

 

 

 

 

26

Image 26
Contents Contents Model MR-G50J-SS-NZVegetable compartment Easy Access Vegetable room, Easy Access Freezer RoomMR-G50J-NZ 1MechanismSpecifications Specifications MR-G50J-NZElectrical Parts Specifications MR-G50J-NZ NSCE001DC1Wiring Diagram Actual Wiring Diagram Unit mm 782 214 284 456 361 745Refrigerant Circuit Function of normal operation Operating mode and Temperature rangeFunction of Operation Panel MR-G50J-NZ Convenient functionThermistor temperature check mode Demonstration mode for shop displayFine adjustment of temperature SettingChange of display Change mode of compressor rotational speedDisplay Changing the rotational speedStatus display of each damper Damper Operation ModeHow to make each damper open or close Display details Error history display modeCheck points and resetting the error history Self-check and error display method and operation Flowchart of SELF-CHECK MR-G50J-NZTroubleshooting with self-check Release of self-check display modeCheck point and treatment Error display and trouble locatingTiming in self-check Display Self-check Ice making cycle Block Diagram of Printed Circuit Board MR-G50J-NZAuto ICE Maker MR-G50J-NZ Automatic ice maker circuitOperation by ice making test Maintenance for water pump and water pipeTroubleshooting for automatic ice-maker Water pipe ·ankT holderControl Flowchart of Trouble Criterion MR-G50J-NZExcessive cooling No cooling, poor cooling Compressor does not operate Poor coolingControl board Filter boardError Abnormality Possible cause Symptom Treatment Inverter-related indication Compressor does not operateError Abnormality Possible cause Symptom Treatment Code E56 StartRefrigerator fan Poor defrostingMotor does not work Excessive cooling Poor cooling CN7SVersa Excessive cooling No cooling poor coolingCompartment/ Ice making compartment Trouble Criterion of Main Parts MR-G50J-NZ Abnormal faulty Compartment Versa compart Abnormal faulty Partment ApproxAbnormal faulty Compartment Connector is at 415Partition V/F Compartment HeaterHeater board Refrigerator Compartment Tray heater Ice trayCheck Method and Criterion Parts Mounted Position Troubleshooting with self-checkComponents Part Name Test Point Diagram of Filter Board MR-G50J-NZ Test Point Diagram of Control Board MR-G50J-NZ + +Names of the Parts Min ChillRight rail of the slide compartment Control boardVertical partition Left rail of the slide compartmentControl panel upper/ lower Duct R upper/ lower Control panel assemblyAutomatic ice maker assembly Partition I/ SPartition V/ F Connector cover right/ leftCover lower Fan grilleCeiling of versa compartment Door switchTank holder Guide properly and works properly Operation panel How to removeRotational heater board Machine chamber fan motor Compressor cover machine chamber fan motorDoor adjustment Dentifying roller sets MarkingElectrical Parts MR-G50J-SS-NZ AbbreviationVegetable compartment Versa compartment Hinge assemblyDoor Parts MR-G50J-SS-NZ 07W 852 Operation panel M20 RoHS Spec Part name Drawing No01W 701 026 Door closer Left M20Body Parts MR-G50J-SS-NZ 520 Water tank assembly 702 Hinge assembly Left/ Lower702 Hinge assembly Right/ Lower M20 AbbreviationNumbers will Accessory and Unit Parts MR-G50J-SS-NZThese part Be informedPage Specifications subject to change without notice