Components/ | Check Method and Criterion |
| Parts Mounted |
Part Name |
| Position | |
|
| ||
Divider | Measure the resistance with a tester. (Ambient temperature : Room temperature) | In partition I/S. | |
heater (I/S) |
|
|
|
| Normal | Abnormal (faulty) |
|
| 9.6k' (Approx.) | Open circuit (∞ ' ) |
|
| While compressor is operating, the heater is turned on. |
| |
| Operation method When compressor stops, the heater is suspended for the |
| |
| first 20 minutes and then reactivated. |
|
|
Rotational | Measure the resistance with a tester. (Ambient temperature : Room temperature) | In the rotational | |
heater board |
|
| heater board of |
|
|
| refrigerator |
|
|
| compartment. |
| Normal | Abnormal (faulty) |
|
| 6.6k' (Approx.) | Open circuit (∞ ' ) |
|
| While compressor is operating, the heater is turned on. |
| |
| Operation method When compressor stops, the heater is suspended for the |
| |
| first 20 minutes and then reactivated. |
|
|
Ice making | Measure the resistance with a tester. (Ambient temperature : Room temperature) | Lower part | |
tray heater |
|
| of ice tray |
| Normal | Abnormal (faulty) |
|
| 4.8k' (Approx.) | Open circuit (∞ ' ) |
|
During CRYSTAL ICE mode
Operation method (The heater is turned on 10 minutes after water is
supplied, until 5~6 hours.)
29