Components/ |
|
|
|
|
|
|
| Check Method and Criterion |
|
| Parts Mounted | ||
Part Name |
|
|
|
|
|
|
|
|
| Position | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Defrost heater |
|
|
|
|
|
|
|
|
|
|
|
| At the drip tray |
Rated input | W | 163 |
|
| |||||||||
|
|
| under the evap- | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| The heater is energized while defrosting. | ||||
| Operation method |
|
|
| orator of the | ||||||||
| (Defrosting is finished when the evaporator is 14± 1.5: or more) | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| freezer |
| Measure the resistance with a tester. (Ambient temperature : Room temperature) | ||||||||||||
| compartment. | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal | Abnormal (faulty) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 325' | Open circuit (∞ ' ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| (Approx.) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vegetable | Measure the resistance with a tester. (Ambient temperature : Room temperature) | In the fan grille | |
compartment |
|
| at the back of |
heater 1 |
|
| vegetable |
|
|
| compartment. |
| Normal | Abnormal (faulty) |
|
| 5.9k' (Approx.) | Open circuit (∞ ' ) |
|
| The heater is turned on when vegetable compartment |
| |
| Operation method thermistor has reached a lower temperature than the set |
| |
| temperature for vegetable compartment. |
| |
Vegetable | Measure the resistance with a tester. (Ambient temperature : Room temperature) | In partition V/F. | |
compartment |
|
|
|
heater 2 |
|
|
|
| Normal | Abnormal (faulty) |
|
| 5.9k' (Approx.) | Open circuit (∞ ' ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| The heater is turned on when vegetable compartment |
| |||
| Operation method | thermistor has reached a lower temperature than the set |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| temperature for vegetable compartment. |
| |||
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Water pipe | Measure the resistance with a tester. (Ambient temperature : Room temperature) | Under the water | |||||||||||||||
heater |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| tank holder. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal | Abnormal (faulty) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6.6k' (Approx.) | Open circuit (∞ ' ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| When |
| ||
| Operation method |
| below, the heater is turned on with energizing rate adjust- |
| |||||||||||||
|
| ed by the set temperature of slide compartment and |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| freezer compartment. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
28