4 Product Operation
Air Flow
IMPORTANT
The unit requires proper air flow to perform at its highest efficiency. Do not block the front grille or internal fans at any time, or the unit will not perform as expected. Do not install the unit behind a door.
Initial Startup
All
IMPORTANT
To turn the unit on or off, press and hold the POWER icon (1) for about ten seconds and release. The display will show the unit set- point temperature when turned on and display OFF when the unit is off.
Electronic Control Panel
Digital Display. Dual Zone Wine Captain Models provide two controlled temperature zones to satisfy the specific storage requirements of your finest wines.
The electronic control with dual digital displays shows a single continuous
Turning the Display Off. Wine Captain Models have a DISPLAY OFF mode available through the control panel. This allows you to control if the display (4 & 5) will be ON or OFF with the door closed. The icon sequence that follows will switch between both modes, On or Off:
1.Press and hold the WARMER icon (2), and simultaneously within five seconds press the ON OFF icon (1) three times.
2.The display will be either visible or dark with the door closed. To return to the previous mode, repeat Step 1.
Dual Temperature Zones
To adjust the set point temperature:
Your unit has been designed to provide two temperature zones (upper and lower) in the cabinet. Each zone can be adjusted within the 4 following temperature ranges:
Wine Captain Temperature Ranges
| Default | Range |
RW (Red Wine) | 55°F | 60° - 50°F |
WW (White Wine) | 50°F | 55°F - 45°F |
SW (Sparkling Wine) | 45°F | 50° - 40°F |
BV (Beverage) | 38°F | 60° - 34°F |
5 | 6 | 7 | 8 | ||||||
| UPPER ZONE CONTROLS |
|
|
|
|
|
|
|
|
Power Warmer Cooler Display |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Display Warmer Cooler Light
LOWER ZONE CONTROLS
1 2 3 4
1.Press and release the desired zone Warmer (2 or 6) icon to put the controller in the SET TEMPERATURE mode. The current range symbol will show on the display. (4 or 5)
2.Within five seconds press the WARMER or COOLER icon to scroll to the desired range (RW, WW, SW, BV).
3.When the desired range is displayed, press the LIGHT (8) icon to display the current
4.Press the WARMER (2 or 6) or COOLER (3 or 7) icon as required to adjust the
5.When the desired
6.Repeat for other zone if desired.
Temperature °F °C Selection.
Easily adjust the display for either type temperature display.
Press and hold the LIGHT icon (8) and simultaneously within five seconds press the COOLER icon (5) three times to change the display (3) as needed.
Temperature Display. Under normal operating conditions the temperatures will fluctuate based on a number of factors. On passive cooled units the temperature will always be cool toward the top and coolest toward the bottom.
To display actual temperature:
1.Press the desired zone WARMER icon (2 or 6) for five seconds. The display (4 or 5) will indicate the actual temperature.
2.After about 5 seconds, the set point temperature will return to the display.
5 |