U-Line 3018 CLR 115 V / 60 Hz quick start Drain Connection, Gravity Drain

Page 7

QUICK START GUIDE

u-line.com

5.Route water supply line in cable clamp and secure with screw.

Drain

Models ending in (-00A, -01A) will not be equipped with factory installed drain pump.

Models ending in (-40A, -41A) will have the factory installed drain pump.

DRAIN CONNECTION

!CAUTION

If your U-Line unit did not come with a factory installed drain pump you must use a gravity style drain connection. For assistance in determining if your unit has a pump please contact U-Line. The floor drain must be large enough to accommodate drainage from all attached drains. Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/ or potentially flowing onto the floor, which may result in personal injury or property damage.

NOTICE

Drain can NOT be located directly below the unit. Unit has a solid base that will not allow the unit to drain below itself.

There is a possibility that hose connections may have loosened during shipment.

Verify all connections and fittings are free from leaks.

GRAVITY DRAIN

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

A gravity drain may be used if:

Drain line has at least a 1" drop per 48" (approximately 2 cm drop per 100 cm) of run.

Drain line does not create traps and is vented per local code.

1.Cut the pre-installed drain tube to length.

2.Connect to your local plumbing per the local code.

3.If necessary, insulate drain line to prevent condensation.

4

Image 7
Contents Quick Start Guide Product Information Property Damage / Injury Concerns Service Information General InquiriesConnect with US Service & Parts Assistance Welcome to U-LINEContents Clear Ice Machines Model ListSafety Alert Definitions Safety and WarningEnvironmental Requirements Prepare Plumbing Water HookupDrain Connection DrainGravity Drain Factory Installed Drain Pump Integrated Door SwingStainless Leveling Information General InstallationInstallation TIP InstallationFirst Use Function Command DISPLAY/OPTIONSICE Cube Thickness Adjustment Control Quick GuideICE Adjust Warranty Sabbath ModeLine Corporation Limited Warranty Quick Start Guide