Ayre Acoustics P-5XE owner manual Customization, Custom Loading Resistors

Page 11

Optimization and

Customization

Technically oriented users may wish to explore additional customization options that are available.

Custom Loading Resistors

When using custom loading Should additional loading values be desired, custom

resistors, leave the loading loading resistors are also easily accommodated. As

switches in the “Up” position there are two types of inputs (balanced and

(47 k). unbalanced), simply connect the desired value of loading resistor to the unused inputs using an appropriate connector (RCA or XLR).

Required materials include a pair of high-quality resistors of the desired value and an additional pair of the appropriate connectors (RCA or XLR). Male polarity connectors are required for the custom loading resistors.

When using a balanced (XLR) connection to the turntable, solder the desired value loading resistors between the center pin and the shell of the additional male RCA connectors. These additional connectors are then inserted into the otherwise unused unbalanced inputs of the P-5xe.

9

Image 11
Contents MC/MM Phono Preamplifier Page Contents Ayre Inputs InstallationLocation R e Outputs AC Power Operation Setting the GainSetting Break-In Setting the LoadingCustom Loading Resistors CustomizationCustom Phono Cables Turntables with RCA Connectors Tonearms with a Mini-DIN Connector Page Female DIN Shield Specifications North American Warranty WarrantyNorth American Warranty Statement International Warranty Place for Revision Page Ayre Acoustics, Inc Central Avenue Boulder, Colorado