SPX Cooling Technologies 05-116E user manual FAN Shaft Sheave, Sheave Alignment

Page 24

Maintenance

sion is the lowest tension at which the belt will not slip under peak load conditions. Check tension frequently during the first 24-48 hours of run-in operation. Overtensioning shortens belt and bearing life. Keep belts free from foreign material which may cause slipping. Never apply belt dress- ing as this will damage the belt and cause early failure. A Dodge® V-Belt Tension Tester is an alternate method for tensioning V-belts. Check with you local belt supplier.

FAN SHAFT

SHEAVE

 

SHEAVE

Figure 3

STRAIGHT EDGE

Sheave Alignment

The motor sheave is to be positioned as close as possible to the motor in order to minimize stress on the motor bushings.

The motor and fan sheaves may have grooves that are not used. The bottom surface of the motor and fan sheaves must be aligned within 18" of each other and level within 12° (18" in 12) in order to not adversely affect belt and sheave life.

Alignment can be achieved by placing a straight edge across the sheaves making sure that it is level and measuring down to the bot- tom surface of both sheaves at four points.

The belt is to be located in the grooves closest to the motor center- line.

24

Image 24
Contents Marley MH Fluid Cooler Page Contents Safety First PreparationFluid Cooler Location Installation Fluid Cooler ShipmentReceiving Fluid Cooler Hoisting Fluid CoolerFluid Cooler Installation Motor Wiring When using a starterWhen using a two-speedstarter When using a VFDInstallation Mechanical Equipment Installation Operation Fluid Cooler Start-UpWater System Operation Fluid Cooler Operation GeneralWintertime Operation Fan acceleration time of 30 seconds per hourOperation Intermittent Wintertime Operation Protection Against Coil FreezingModel Coil Volume Water Treatment and Blowdown Maintaining Water QualityMaintenance Fluid Cooler CleaningBlowdown Belt Tensioning Jacking Screws FAN Shaft Sheave Sheave AlignmentFluid Cooler Maintenance Bushing Fastener Torque ValuesMaintenance Motor Relubrication Instructions Seasonal Shutdown Instructions Prolonged Shutdown SPX Cooling Technologies Services Maintenance Schedule Troubleshooting Trouble Cause RemedyTroubleshooting Additional Information Page Manual 05-116E

05-116E specifications

SPX Cooling Technologies 05-116E is a state-of-the-art cooling tower aimed at providing exceptional cooling efficiency for industrial and commercial applications. Known for its robust design and advanced features, the 05-116E model promises to deliver reliable performance under various operational conditions.

One of the most notable features of the 05-116E is its energy-efficient operation. The design incorporates advanced thermal performance technologies that allow this cooling tower to maximize heat exchange while minimizing energy consumption. This efficiency not only translates into cost savings for users but also reduces the environmental impact, making it a sustainable choice in today’s eco-conscious market.

The 05-116E utilizes a fiberglass-reinforced plastic construction, which contributes to its durability and resistance to corrosion. This is particularly advantageous for installations in harsh environments, where exposure to elements like chlorine or salt can significantly degrade the performance of traditional materials. The lightweight build facilitates easier installation and maintenance, further enhancing the operational effectiveness of the cooling tower.

Another key characteristic of the SPX Cooling Technologies 05-116E is its modular design. This feature allows for scalable configurations, enabling users to customize their cooling solution according to specific capacity requirements. Whether for a small facility or a large industrial operation, the modularity ensures that optimal cooling performance is maintained at all scales.

The cooling tower is also equipped with innovative fan technology that promotes quieter operation while simultaneously increasing airflow efficiency. This is particularly beneficial in urban or residential areas where noise reduction is a priority. Coupled with effective vibration dampening mechanisms, the 05-116E ensures a peaceful operating environment.

Moreover, the 05-116E model incorporates advanced water management systems, designed to minimize water usage and enhance water treatment practices. This not only conserves valuable resources but also ensures that the cooling processes remain hygienic and efficient throughout the operational lifespan.

In summary, the SPX Cooling Technologies 05-116E stands as a top-tier choice for those seeking a reliable, efficient, and durable cooling tower solution. With its energy-saving features, robust construction, modular capability, quiet operation, and advanced water management systems, it fulfills the demanding requirements of modern cooling applications across various industries.