Smeg NCT685CHK, NCT685BHK, NCT685BSG manual Natural gas G20 2.0 kPa

Page 10

Instructions for the installer

 

 

 

 

 

Rated

 

 

 

 

 

 

Burner

 

 

 

heating

 

 

Natural gas – G20 2.0 kPa

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

Reduced flowrate

 

 

 

 

 

 

 

 

1/100 mm

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1.05

 

73

380

 

 

 

 

 

 

 

 

 

 

 

 

Semirapid

 

1.65

 

92

380

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

2.55

 

115

750

 

 

 

 

 

 

 

 

 

 

 

Rapid large

3.1

 

126

800

 

 

 

 

 

 

 

 

 

 

 

 

Fish pan

 

1.8

 

95

100

 

 

 

 

 

 

 

 

 

 

 

 

Ultra rapid

 

3.3

 

130

1400

 

 

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

 

0.8

 

 

67

 

 

380

crown

 

 

 

 

 

 

 

 

 

 

 

External

 

3.3

130

 

900

 

 

 

 

 

 

 

 

 

 

 

 

12

Image 10
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Positioning of the HOB Instructions for the installerAttachment to support structure Electrical Connection GAS Connection Ventilation of rooms Connection to LPGDischarge of combustion products Adjustment for Different Types of GAS Removing the hobNozzle replacement and primary air adjustment 1700 240 236 Double Internal 380 Crown External 1200Natural gas G20 2.0 kPa G20 Regulation of primary airTown gas G110 0.8 kPa G30/G31 G110 KPaRegulation of turndown rate for natural gas or town gas Final OperationsRegulation of turndown rate for LPG Burners Arrangement of the burners on the hobLubrication of gas taps This must be done by a qualified technicianInstructions for the user Using the HOBIgnition of the burners Diameter of the pans Practical advice for using the burnersBurners Min. and max. in cm Cleaning Cleaning and MaintenanceCleaning of cooking hob components Cover Cod /B