Smeg NCT685BSG, NCT685BHK Regulation of primary air, Town gas G110 0.8 kPa, G20, G30/G31 G110 KPa

Page 11

Instructions for the installer

Burner

 

 

 

Rated

 

Town gas G110 – 0.8 kPa

 

 

 

heating

 

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

Reduced flowrate

 

 

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1.05

132

380

 

 

 

 

 

 

 

 

 

 

Semirapid

 

1.65

165

380

 

 

 

 

 

 

 

 

 

 

Rapid

 

2.55

210

600

 

 

 

 

 

 

 

 

 

Rapid large

3.1

240

800

 

 

 

 

 

 

 

 

 

 

Fish pan

 

1.8

177

750

 

 

 

 

 

 

 

 

 

 

Ultra rapid

 

3.3

250

900

 

 

 

 

 

 

 

 

 

 

Double

 

Internal

 

 

0.8

 

115

 

380

crown

 

 

 

 

 

 

 

 

 

 

External

 

3.3

250

900

 

 

 

 

 

 

 

 

 

 

Regulation of primary air

Referred to distance “X” in mm.

Burner

 

 

 

G20

 

 

 

2.0 kPa

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.5

 

 

 

 

 

 

Semirapid (2)

 

1.5

 

 

 

 

 

 

Rapid (3)

 

1.0

 

 

 

 

 

 

Rapid large (4)

1.5

 

 

 

 

 

 

Fish pan (7)

 

2.5

 

 

 

 

 

 

Ultra rapid (5)

 

 

1.5

 

 

 

 

 

 

Double

 

Internal

 

 

1.5

crown (6)

 

 

 

 

 

 

External

 

1.5

 

 

 

 

 

 

G30/G31

 

G110

2.8 kPa

 

0.8 kPa

1.00.5

1.50.5

1.51.0

2.51.0

2.01.0

2.51.0

1.50.5

4.01.0

13

Image 11
Contents Contents Instructions for Safe and Proper USE IntroductionIntroduction Attachment to support structure Instructions for the installerPositioning of the HOB Electrical Connection GAS Connection Discharge of combustion products Connection to LPGVentilation of rooms Removing the hob Adjustment for Different Types of GAS1700 240 236 Double Internal 380 Crown External 1200 Nozzle replacement and primary air adjustmentNatural gas G20 2.0 kPa G30/G31 G110 KPa Regulation of primary airTown gas G110 0.8 kPa G20Regulation of turndown rate for LPG Final OperationsRegulation of turndown rate for natural gas or town gas This must be done by a qualified technician Arrangement of the burners on the hobLubrication of gas taps BurnersIgnition of the burners Using the HOBInstructions for the user Burners Min. and max. in cm Practical advice for using the burnersDiameter of the pans Cleaning of cooking hob components Cleaning and MaintenanceCleaning Cover Cod /B