Smeg NCT685BSG, NCT685BHK manual Instructions for the user, Using the HOB, Ignition of the burners

Page 14

Instructions for the user

7 USING THE HOB

Before turning on the burners, make sure that the burner rings, caps and grids have been fitted correctly.

In the ultrarapid burner, notch A must be aligned with pin B. Grid C provided is intended for use with woks (Chinese pans).

Adapter D comes only with open grids models and is intended for use with small sized vessels.

7.1Ignition of the burners

The device is fit with electronic ignition. Simply press and simultaneously turn the knob counter-clockwise on the low point flame symbol, until the burner is ignited.

Concerning models with valves, push the knob for approximately 2 seconds in order to keep the flame burning and to activate the safety device.

The burner might go off when the knob is released. In this case repeat the aforesaid operation keeping the knob pressed for more than 2 seconds.

(Only where applicable)

Double-crown burners, controlled by two knobs, feature two ribs, a long one corresponding to the small inner burner and a short one to the outer burner.

Double-crown burners comprise an auxiliary and a rapid burner, controlled by two different knobs which allow both burners to be used at the same time or to select one or the other as required.

Should the burners go off accidentally in the models with valves, a safety device will trip after approximately 20 seconds to block the gas outlet even if the cock is open.

16

Image 14
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Attachment to support structure Instructions for the installerPositioning of the HOB Electrical Connection GAS Connection Discharge of combustion products Connection to LPGVentilation of rooms Adjustment for Different Types of GAS Removing the hobNozzle replacement and primary air adjustment 1700 240 236 Double Internal 380 Crown External 1200Natural gas G20 2.0 kPa G20 Regulation of primary airTown gas G110 0.8 kPa G30/G31 G110 KPaRegulation of turndown rate for LPG Final OperationsRegulation of turndown rate for natural gas or town gas Burners Arrangement of the burners on the hobLubrication of gas taps This must be done by a qualified technicianIgnition of the burners Using the HOBInstructions for the user Burners Min. and max. in cm Practical advice for using the burnersDiameter of the pans Cleaning of cooking hob components Cleaning and MaintenanceCleaning Cover Cod /B