Smeg GKC95-3, GKC64-3 Connection to LPG, Ventilation of rooms, Discharge of combustion products

Page 8

Instructions for the installer

4.1Connection to LPG

Use a pressure regulator and make the connection to the tank according to the provisions of standards regulations in force. Make sure that feed pressure conforms to the levels shown in the table in paragraph “5.3 Regulation for LPG”.

4.2Ventilation of rooms

The hob may be installed only in rooms with permanent ventilation, as required by standards regulations in force. The room in which the hob is installed must have sufficient air flow to satisfy the requirements of normal gas combustion and of necessary air exchange in the room. The air intakes, protected by screens, must be appropriately sized (regulations in force) and placed so as not to be blocked in any way. The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking, and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased.

4.3Discharge of combustion products

Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration.

An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity.

30

Image 8
Contents Contents Introduction Instructions for Safe and Proper USEIntroduction Attachment to support structure Instructions for the installerPositioning of the HOB Fixing 90 cm hobs on 60 cm base unit Electrical Connection GAS Connection Discharge of combustion products Connection to LPGVentilation of rooms Regulation for LPG Adaptation to Different Types of GASRemoving the hob models with integrated control panel Auxiliary 400 Semi-rapid Regulation for G25/25 mbar Regulation of primary air Cm hobs with separable control panel Burner G25 G30/G31Cm hobs with separable control panel Burner G25 G30/G31Regulation of minimum for LPG Final OperationsRegulation of minimum for natural gas 60 cm. hob 90 cm. hobLubrication of gas taps Using the HOB Practical advice for using the burnersInstructions for the user Ignition of the burnersUsing the electric elements Diameter of the pansBurners Min. and max. en cm Turning on electric elementsUsing a griddle plate To use correctly remember toCleaning and Maintenance CleaningRegular daily cleaning of the hob Food stains or residuesCleaning of cooking hob components Ignition plugs and safety devicesElectric element Cover