5 ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the electrical socket.

The hob has been inspected for G25 (2L3B/P) natural gas at a pressure of 25 mbar. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted.

To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph.

5.1Removing the separable control panel (models with

separable control panel)

1.Remove the knobs and the knob guard tube “A” by pulling them up;

2.Use a crosshead screwdriver to remove the screws and the two cylindrical supports “B”;

3.Raise the left-hand side of the control panel slightly and shift it to the right to remove it completely;

4.In models with electric hotplate, the body of the pilot light has to be removed to free the control panel;

5.2Removing the hob (models with integrated control panel)

1.Remove the knobs, the griddles, the burner caps, the flame caps and the two rear plugs;

2.Remove the screws “A” which fix the burner supports;

3.Raise the hob, sliding it off the ignition plugs and/or the thermocouples and the gas tap rods;

5.3Regulation for LPG

Check that the connection has been made as described in the “Gas connection” section.

Undo the screw “D” and push the air regulator “C” fully down. Use a spanner to remove the nozzles “B” and fit those of suitable type

31

Image 9
Contents Contents Instructions for Safe and Proper USE IntroductionIntroduction Instructions for the installer Positioning of the HOBAttachment to support structure Fixing 90 cm hobs on 60 cm base unit Electrical Connection GAS Connection Connection to LPG Ventilation of roomsDischarge of combustion products Adaptation to Different Types of GAS Removing the hob models with integrated control panelRegulation for LPG Auxiliary 400 Semi-rapid Regulation for G25/25 mbar Cm hobs with separable control panel Burner G25 G30/G31 Regulation of primary airCm hobs with separable control panel Burner G25 G30/G31Final Operations Regulation of minimum for natural gasRegulation of minimum for LPG 90 cm. hob 60 cm. hobLubrication of gas taps Practical advice for using the burners Using the HOBInstructions for the user Ignition of the burnersDiameter of the pans Using the electric elementsBurners Min. and max. en cm Turning on electric elementsTo use correctly remember to Using a griddle plateCleaning Cleaning and MaintenanceRegular daily cleaning of the hob Food stains or residuesIgnition plugs and safety devices Cleaning of cooking hob componentsElectric element Cover