Smeg ER12150EU, ER12550EU, ER12150PP, ER12150NL, ER12550NL manual Electrical Connection

Page 5

Instructions for the installer

3. ELECTRICAL CONNECTION

Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason.

The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded.

On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

Do not use reducers, adapters or shunts.

If the power cable is replaced, the wire section on the new cable must

not be less than 0.75 mm2 (3 x 0.75 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram.

L = brown N = blue

= yellow-green

The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob.

22

Image 5
Contents Contents Instructions for Safe and Proper USE IntroductionPlate on the Casing Must not be Removed Positioning of HOB Instructions for the installerElectrical Connection GAS Connection Discharge of combustion products Connection to LPGVentilation of rooms Removing the hob Adaptation to Different Types of GASCapacity Regulation for LPGRegulation of primary air Regulation for natural gasRegulation of minimum for LPG Final OperationsRegulation of minimum for natural gas Lubrication of gas taps Arrangement of burners on hobIgnition of the burners with safety device Using the HOBPractical advice for using the burners Instructions for the userDiameter of containers Cleaning and MaintenanceCleaning Ignition plugs and safety devices Cleaning of cooking hob components