Instructions for the installer
9. GAS CONNECTION
Before installation, make sure that the local distribution conditions (nature and pressure of the gas) and the state of regulation of the appliance are compatible.
Connection to the gas supply network can be made using a rigid copper hose or a flexible steel hose with a continuous wall and in compliance with the guidelines established by the standard
Once the operation is complete, check the hose fittings for leaks using a soapy solution; never use a flame. The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar.
For supplying it with other types of gas, see chapter "10. ADAPTATION TO DIFFERENT TYPES OF GAS".
The gas inlet connection is threaded ½” external gas (ISO
Connection with rigid copper
hose: The connection to the gas supply network must be carried out in such a way that it does not cause stresses of any type on the appliance. The connection can be made using the adapter unit D with double cone, always inserting the supplied gasket C in between.
Connection with flexible steel
hose: Use only continuous wall stainless steel hoses that comply with standard
Installation with the flexible hose must be carried out so that the length of the piping does not exceed 2 metres fully extended; make sure that the hoses do not come into contact with moving parts and that they are not crushed in any way.
9.1Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following the guidelines established by the regulations in force.
Make sure that the supply pressure complies with the values indicated in the table at point "10.2 Burner and nozzle characteristics table".
36