Smeg PS906 manual Room ventilation, Extraction of the products of combustion

Page 16

Instructions for the installer

9.2Room ventilation

The appliance may only be installed in permanently ventilated rooms, as specified by the standard UNI-CIG 7129 / 7131. In the room where the appliance is installed, there must be an adequate air flow to meet the requirements of normal gas combustion and the necessary ventilation of the room itself. The air vent, protected by grilles, must be suitably dimensioned (UNI CIG 7129 / 7131) and positioned so that no part of it is obstructed, even partially. The room must be kept adequately ventilated in order to eliminate the heat and humidity produced by cooking: in particular, after prolonged use, it is recommended to open a window or to increase the speed of any ventilators.

9.3Extraction of the products of combustion

Extraction of the products of combustion must be ensured by means of hoods connected to a natural draught chimney whose efficiency is assured or via forced extraction. An efficient extraction system requires precision planning by a specialist qualified in this area and must comply with the positions and distances indicated by the regulations. When the job is complete, the installer must issue a certificate of conformity.

37

Image 16
Contents Contents Precautions for use Instructions for USEInstructions for disposal Instructions for Disposal OUR Environmental CareSafety instructions Safety InstructionsInstructions for the user Before InstallationKnow Your Appliance Using the HOB Gas hobPractical tips for using the burners Pan diametersCleaning and Maintenance Cleaning stainless steelCleaning the gas components Ordinary daily cleaningInstructions for the installer Installing the AppliancePositioning in the counter top Fixing to the supporting structureInstructions for the installer Fixing to the electric model support structure Instructions for the installer Electrical connection Do not remove this plate for any reasonInstructions for the installer GAS Connection Connection to liquid gasConnection with rigid copper Connection with flexible steelRoom ventilation Extraction of the products of combustionReplacement of nozzles on the cooker hob Adaptation to Different Types of GASBurner and nozzle characteristics table Liquid GAS G30/G31 28/37 mbarAdjusting the minimum for town and natural gas Adjusting the minimum for liquid gasFinal Operations for GAS Appliances Lubrication of gas taps