15.2 Burner and Nozzle Data Tables
| Rated heat |
|
|
|
|
|
|
Burner | capacity |
| BOTTLED GAS - G30/G31 30/37 mbar |
|
| ||
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle | Net | Net | Net |
| |
|
| diameter | 1/100 | heat capacity | g/h G30 | g/h G31 |
|
|
| 1/100 mm | mm | (W) |
|
|
|
|
|
|
|
|
|
|
|
Auxiliary | 1.0 | 50 | 30 | 350 | 72 | 71 |
|
Semirapid | 1.75 | 65 | 33 | 450 | 127 | 125 |
|
Triple Flame | 3.2 | 91 | 65 | 1500 | 233 | 229 |
|
|
|
|
|
|
|
|
|
| Rated heat |
|
|
|
|
|
|
Burner | capacity |
| NATURAL GAS – G20 20 mbar |
|
| ||
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle |
| Net |
|
|
|
|
| diameter |
| heat capacity |
|
|
|
|
| 1/100 mm |
| (W) |
|
|
|
|
|
|
|
|
|
|
Auxiliary | 1.0 |
| 72 |
| 350 |
|
|
Semirapid | 1.75 |
| 97 |
| 450 |
|
|
Triple Flame | 3.2 |
| 125 |
| 1500 |
|
|
15.3 Hob burner layout |
|
|
|
|
| ||
|
| BURNERS | min. and max. Ø |
|
|
| |
|
|
|
| (in cm) |
|
|
|
|
| 1. Auxiliary | 12 - 14 |
|
|
| |
|
| 2. Semirapid | 16 - 24 |
|
|
| |
|
| 4. Triple Flame | 18 - 26 |
|
|
|