5.2 Regulation for LPG

Instructions for the installer

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

BurnerheatingLPG – G30/G31 28/37 mbar capacity

(kW)

 

 

 

 

 

 

Nozzle

 

 

 

 

 

 

diameter

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

Auxiliary (1)

 

 

 

1.05

 

48

 

 

 

 

 

 

Semi-rapid (2)

 

 

 

1.65

 

62

 

 

 

 

 

 

Rapid (3)

 

 

 

3.1

 

85

 

 

 

 

 

 

Ultra rapid (4)

 

 

 

3.3

 

87

 

 

 

 

 

 

 

Double crown

 

internal (5)

 

1.15

 

48

 

 

external (5)

 

 

 

 

 

 

 

3.8

 

92

 

 

 

 

 

 

 

Fish pan (6)

 

 

 

2.9

 

82

By-pass

mm

1/100

30

33 (*)

30

33 (*)

43

45 (*)

55

 

65 (*)

 

 

30

 

33 (*)

55

65 (*)

43

45 (*)

Reduced

flowrate

(W)

380

380

750

1200

380

1200

800

 

Flowrate

 

Flowrate

 

 

 

 

 

g/h G30

 

g/h G31

 

 

 

 

 

 

76

75

120

118

225

222

240236

76 75

240

236

211

207

(*) By-pass value for valveless appliances.

31

Image 10
Contents Contents THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE Introduction1. INSTRUCTIONS FOR SAFE AND PROPER USE NEVER UNPLUG BY PULLING ON THE CABLETHE PLATE ON THE CASING MUST NOT BE REMOVED 2. POSITIONING OF HOB Instructions for the installer2.1.1 Attachment to support structure Instructions for the installer 3. ELECTRICAL CONNECTION 4. GAS CONNECTION 4.2 Ventilation of rooms 4.1 Connection to LPG4.3 Discharge of combustion products 5. ADAPTATION TO DIFFERENT TYPES OF GAS 5.1 Removing the hob5.2 Regulation for LPG Rated BurnerheatingLPG - G30/G31 28/37 mbar capacity kW5.4 Regulation for town gas 5.3 Regulation for natural gasheating 5.5 Regulation of primary air Referred to distance “X” in mm6.1 Regulation of minimum for natural gas 6. FINAL OPERATIONS6.2 Regulation of minimum for LPG This must be done by a qualified technician 6.3 Arrangement of burners on hob6.4 Lubrication of gas taps BURNERS7. USING THE HOB Instructions for the user7.4 Using a griddle plate 7.2 Practical advice for using the burners7.3 Diameter of containers 7.5 Electric elements 7.5.2 Using the electric elements7.5.1 Turning on electric elements To use correctly remember to Before any intervention, disconnect the power supply of the device 8. CLEANING AND MAINTENANCENever use a steam jet to clean the appliance 8.1.1 Regular daily cleaning of the hob8.2.2 The electric element 8.2.1 Ignition plugs and safety devicesCAUTION do not wash these components in a dishwasher 8.2.3 The cover