Smeg A11A-5 manual Gas connection

Page 5

Instructions for the installer

2.2 Gas connection

This appliance is suitable for installation with Natural Gas or LPG. Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of LPG appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BPS connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

(a)- annealed copper pipe; or

(b)- a hose assembly complying with requirements of AS 1869 - class B or equivalent.

The cooker must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the cooker is operated make certain all relevant parts are placed in the correct position.

When the installation is completed the installation connections of cooker will require to be leak tested, the burner operating pressure and flame checked and adjusted.

Warranty service calls do not cover these adjustments!

To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed.

N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0kPa after installation.

L.P.G. Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2.75kPa.

7

Image 5
Contents Contents Instructions for Safe and Proper USE IntroductionPlate Must not be Removed This rating plate must never be removed Installation of the ApplianceElectrical connection Gas connection Room ventilation Clearance above and around domestic cookers Requirements Instruction for wall fixing Adaptation to Different Types of GAS Replacement of nozzles on the hobArrangement of burners on cooking hob Burner and nozzle characteristics tableFinal Operations Adjustment of minimum for natural gasPositioning and levelling of the appliance Lubrication of gas tapsDescription of Controls Description of SymbolsFront control panel Thermostat KnobCooking HOB Burner Command Knob Function Switch KnobList of Functions Setting the timeElectronic Analogue Clock Minute-minder Programming Demo Function Lighting of the cooking hob burners USE of the Cooking HOBDiameter of containers Practical advice for using the cooking hob burnersOven Light USE of the OvenAvailable Accessories Traditional cooking Function Switch Thermostat Selector Switch from 50 to 250CCooking Hints Hot-air cooking Function Switch Thermostat Switch AT MaximumGrill cooking Make sure that the oven door is closed during cookingFunction Switch Thermostat Switch in Position Function Switch Thermostat Switch from 50 to 250CHot-air grilling DefrostingSpit cooking Cleaning of cooking hob components Cleaning and MaintenanceCleaning stainless steel Do not USE a Steam JET for Cleaning the Inside of the Oven Cleaning of the ovenBurner caps, flame cap crowns and burners Ignition plugs and thermocouplesUsing the self-cleaning liners Self-cleaning linersLooking after the self-cleaning liners Assembling the self-cleaning linersReplacement of light bulb Extraordinary MaintenanceDoor glass Removing the doorOven door seal Preventive maintenance Problems and CausesProblem Cause What to do