Instructions for the installer
3.2 Burner and nozzle characteristics table
Burner |
|
| ULPG (PROPANE) – 2.75 KPa | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nominal gas consumption | Injector | |
|
|
| (MJ/h) |
| (mm) |
|
|
|
|
| |
Auxiliary |
|
| 3.9 |
| 0.54 |
|
|
|
| ||
Semi rapid |
|
| 6.3 |
| 0.68 |
|
|
|
| ||
Rapid |
|
| 10.8 |
| 0.88 |
|
|
|
| ||
WOK |
|
| 12.8 |
| 1.00 |
|
|
|
| ||
Burner |
|
| NG – 1.0 KPa | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nominal gas consumption |
| Injector |
|
|
| (MJ/h) |
| (mm) |
|
|
|
| ||
Auxiliary |
|
| 3.7 |
| 0.90 |
|
|
|
| ||
Semi rapid |
|
| 6.5 |
| 1.20 |
|
|
|
| ||
Rapid |
|
| 10.9 |
| 1.55 |
|
|
|
| ||
WOK |
|
| 12.7 |
| 1.75 |
| 3.3 Arrangement of burners on cooking hob | ||||
|
|
| BURNERS | ||
| 1 | Auxiliary | |||
| 2 | Semi rapid | |||
| 3 | Rapid | |||
| 4 | WOK | |||
| 5 | WOK |
4. FINAL OPERATIONS
After replacing the nozzles, reposition the
After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.
14