Sub-Zero 315 manual Maintenanceadjustments

Page 18

MAINTENANCEADJUSTMENTS

Winterizing

1)Clean the ice making system.

2)Turn off the water supply.

3)Drain the water reservoir. Remove the pump hose.

4)Disconnect the incoming water line at the inlet water valve.

5)Remove control box cover and turn the timer into the harvest cycle.

6)With the ice maker operating, blow air through the inlet water valve; a tire pump could do the job.

7)Drain pump models should have about 1/2 gallon of RV antifreeze (propylene glycol) poured into the ice storage bin drain.

IMPORTANT NOTE: Automotive antifreeze must NOT be used.

8)Replace control box cover. Switch off and unplug the ice maker.

NOTE: To use after winterizing, reconnect pump hose and water line. Repeat the initial start up on page 14.

There are three items that may be adjusted: cube size, bin ice level and harvest time.

IMPORTANT NOTE: Cube size and harvest time adjust- ments should only be done by a qualified service person.

Cube Size Adjustment

The cube size control should only be adjusted to bring the cubes to the correct shape, the overall size cannot be adjusted. Try to adjust the cube size control when the ice maker is in the harvest cycle, or in the first 10 minutes of the freeze cycle.

1)Open the door and remove the control box cover.

2)Locate the cube size adjustment screw, and to make fuller cubes, turn the screw clockwise about 1/4 turn. This will make the freezing cycle longer.

3)To shorten the freezing cycle and make cubes that are not as full, turn the adjustment screw 1/4 turn coun- terclockwise.

4)After the next freezing cycle, the cubes should have responded to the adjustment, if another adjustment is required, do it early in the freeze cycle.

Cube Size Adjustment

Cube Size Adjustment

18

Image 18
Contents Model ICE Maker Model 315 ICE Maker IntroductionPRE-INSTALLATION Model 315 FeaturesArea Requirements Installations Over a Crawl Space or Base Installation PRE-INSTALLATION SpecificationsPlace ice maker in front of installed location. Adjust Completing the Installation Panel Considerations Models 315 and 315P Door Panel Installation Degree Door Stop Installation Check List Operation Ice Production Cleaning Cleaning the Ice Making System Maintenanceadjustments Adjustments Troubleshooting Condenser completely blocked up, needs cleaning Warranty Sub-Zero Protection PlanService Sub-Zero Freezer Company, Inc