P R O 4 8 I N S T A L L A T I O N I N S T R U C T I O N S
D O O R A D J U S T M E N T
D O O R H I N G E A D J U S T M E N T
The door must be removed to adjust door hinges. To remove the door, lift up the vent portion of the top grille, open the door to about 45° and lift the door off the cabinet hinges. Remove the hinge pins.
Loosen the two door hinge fasteners, slide hinge to the desired position and retighten the fasteners. Refer to the illustrations below. Rein- stall hinge pins and door. Check alignment and door seal. Close the vent portion of the top grille.
When adjusting cabinet and door hinges, it is important to keep the hinges parallel to the face of the door and side of the cabinet. The door switch will not function if the hinges are excessively misaligned, which will cause the lights to stay on and the fan to not operate. This will result in elevated cabinet temperatures. After hinge adjustments are made, check that the door switch is functioning properly.
Door hinge adjustment | Door hinge adjustment |
18